Final | 6/18/2015 | 6/19/2015 | 6/19/2015 | A | PASS |
Rock A. Hudson
|
|
|
call ###-#### for access Phone #: ###-#### Inspection requested via web by Heath Thomas Final ok
|
Rough-In Permanent Service | 4/13/2015 | 4/13/2015 | 4/13/2015 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Heath Thomas rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 4/9/2015 | 4/10/2015 | 4/10/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Heath Thomas 314.16(A)- 2 1/8"x4"x1 1/2" metal box has 10.3 cubic inch allowance 14 cubic inches wire and device installed. 334.30- UF shall be secured with in 12" of all boxes. Island
|
Issue PAID IN FULL permit | | | 3/4/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/4/2015 | | DONE |
|
|
|
This permit was created on the web by Heath Thomas
|