Final | 4/4/2016 | 4/4/2016 | 4/4/2016 | P | PASS |
Eric Story
|
|
|
Please call ahead for access - Annie Phone #: ###-#### corrections fixed final ok
|
Final | 2/26/2016 | 3/1/2016 | 3/1/2016 | A | FAIL |
Eric Story
|
|
|
would like call ahead; Shane Phone #: ###-#### 210.8 all receptacles serving counter top in a kitchen shall have GFCI protection 210.12 AFCI protection required for smoke detectors 334.12 type NM cable shall not be used in a wet location
|
Final | 2/19/2016 | 2/19/2016 | 2/19/2016 | P | FAIL |
Eric Story
|
|
|
Shane-please call meet for access Phone #: ###-#### 210.8 GFCI protection for all receptacles serving counter top 210.12 AFCI for all bedrooms @ smokes 406.4(d)(6) all outdoor receptacles shall be weather resistant and have a listed cover 330.30 MC shall be supported with 12" of a box 334.12 type NM cable shall ot be installed in a wet location 210.4(b) multi wire branch circuits shall open all ungrounded conductors 422.31 disconecting for fixed appliances need lockouts 314.25 blanks needed on open boxes 408.38 panelboards shall be deadfronted
|
Electrical Rough-In | 3/20/2015 | 3/20/2015 | 3/20/2015 | P | PASS |
Daryl DeGrange
|
|
|
Shane Phone #: ###-#### correction completed rough-in ok cover
|
Electrical Rough-In | 3/19/2015 | 3/20/2015 | 3/20/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Shane Phone #: ###-#### Corrections not complete. nail plates, support NM above boxes, additional ground rod not installed.
|
Electrical Rough-In | 3/12/2015 | 3/19/2015 | 3/19/2015 | P | FAIL |
Rex Boyles
|
|
|
Shane Phone #: ###-#### 334.30-nm cable shall be supported and secured within 12 " of box and every 41/2 feet. 300.4(A)(1)-where a cable is ran thru bored holes, no more than 11/4" from hole to face of stud. 210.52(A)(1)-receptacles shall be installed so that no point measured horizontally along the floorline of any wall space is more than 6 foot from a recetacle. 250.53(2)-a single ground rod shall be supplemented by an additional ground rod.
|
Electrical Rough-In | 3/10/2015 | 3/13/2015 | 3/13/2015 | P | CANC |
Cevyn Recla
|
|
|
Shane Phone #: ###-####
|
Issue PAID IN FULL permit | | | 3/10/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
(F) Reprint permit | | | 3/10/2015 | | DONE |
|
|
|
|
Application received | | | 3/10/2015 | | |
|
|
|
|