Final | 4/28/2015 | 4/29/2015 | 4/29/2015 | A | PASS |
Daryl DeGrange
|
|
|
If you have questions, please call Clay. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan correction completed, final ok
|
Electrical Rough-In | 4/2/2015 | 4/10/2015 | 4/10/2015 | P | DONE |
Rock A. Hudson
|
|
|
Check for illegal wiring progress back walkway and to carport. Property management working with contractor to repair wiring not up to code.
|
Permanent Service | 3/30/2015 | 4/1/2015 | 4/1/2015 | P | PASS |
Rock A. Hudson
|
|
|
Jake will be on site ###-####. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan p/s o/h rec ok
|
Electrical Rough-In | 4/1/2015 | 4/1/2015 | 4/1/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Jake will be on site ###-####. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan Due to previous work performed without pulling permits wiring in overhead walkway and carport shall be replaced with wiring method listed for area. Will check after 7 working days 4/10/15 to ensure steps are being taken to correct illegal installation. If ignored steps will be taken to disconnect power until corrected. Section 4-05-32 CODE VIOLATION NOT TO BE RETAINED When altering a pre-existing electrical wire, equipment, apparatus or fixture, or adding any new wiring, the existing electrical wiring in close proximity shall be in accordance with the present code. (6338, Added, 08/03/2004) 334.12 Uses Not Permitted. (B) Types NM and NMS. Types NM and NMS cables shall not be used under the following conditions or in the following locations: (4) In wet or damp locations 334.15 Exposed Work. In exposed work, except as provided in 300.11(A), cable shall be installed as specified in 334.15 (B) Protection from Physical Damage.
|
Conference | 3/23/2015 | 3/24/2015 | 3/24/2015 | P | DONE |
Rock A. Hudson
|
|
|
Please give me a half hour heads up so I can meet you out there. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan Discussed requirements for service change to eliminate tripping due to overload on house panel that feeds community laundry room. Shall up size service to house panel, fuse down feeders to appartments due to SER cable sub feeds, raise riser over flat roof, relocate house panel in laundry room panel to provide work space, did permit search no other recent permits exist. Noticed dated Dec 2013 NM cable ran outdoors under walkway roof to carport. Contractor to inform building management all needs replaced with listed materials for locations.
|
Issue PAID IN FULL permit | | | 3/23/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/23/2015 | | DONE |
|
|
|
This permit was created on the web by Clay Morgan
|
First Notice | 4/29/2015 | 4/29/2015 | | | |
Daryl DeGrange
|
|
|
|