Information based on query as of Friday, August 16, 2024.
Permit Information
Permit NumberELE15-00970
StatusFinaled
Name GOLDEN ELECTRIC
Site Address 1403 N 10TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: demo all existing knob and tube wiring. Rewire entire residence and new detached garage.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/30/20159/30/20159/30/2015APASS
DetailsEric Story
John is available and should be on site Phone #: ###-#### Inspection requested via web by John Harvey final ok
Final9/29/20159/29/20159/29/2015PFAIL
DetailsEric Story
Call Tim if any issues

Thank you Phone #: ###-#### Inspection requested via web by John Harvey 110.12 (a) all unused openings shall be closed 2" opening in panel 210.12 arc fault protection required for bedroom and smokes not GFCI protection
Final9/28/20159/28/20159/28/2015PFAIL
DetailsEric Story
House is open. John is out of town Phone #: ###-#### Inspection requested via web by John Harvey 210.52(c) (1) a receptacle shall installed at each counter top space wider than 12" 210.12 arc fault protection required for bedrooms including smoke detectors 422.31 permanently installed appliances shall have a means of lockout Oven,micro,hood,dishwasher/downstairs living room in-op upstairs receptacles in built in cabinet need extended exterior receptacle not finished
Electrical Rough-In7/6/20157/7/20157/7/2015APASS
DetailsEric Story
Main level master floor heat only



John is out of town. The general contractor is available if any problems and will call john Phone #: ###-#### Inspection requested via web by John Harvey master bath floor heat ok cover
Electrical Rough-In6/22/20156/22/20156/22/2015PPASS
DetailsEric Story
Garage rough in only.

John is currently out of town. Call Tim if any problems. Thank you much. Phone #: ###-#### Inspection requested via web by John Harvey rough-in detached garage ok cover
Rough-In Permanent Service5/13/20155/13/20155/13/2015PPASS
DetailsDaryl DeGrange
James is on site. Inspect meter panel so we can swing temp service to permanent.

Thank you Phone #: ###-#### Inspection requested via web by John Harvey p/s o/h rec ok
Electrical Rough-In4/15/20154/16/20154/16/2015PPASS
DetailsDaryl DeGrange
Call john if any issues. Gate code to get into property is 1403
Phone #: ###-#### Inspection requested via web by John Harvey rough-in ok cover
Temporary Service4/9/20154/9/20154/9/2015PCANC
DetailsRock A. Hudson
John is out of town until later today. Call Tim if any issues. This inspection is only for trench inspection. Excavator is on site and is currently digging nearby sewer. Electrical conduit has been installed and photos have been taken Phone #: ###-#### Inspection requested via web by John Harvey Needed rough in inspection
Electrical Rough-In4/9/20154/9/20154/9/2015PPASS
DetailsRock A. Hudson
John is out of town until later today. Call Tim if any issues. This inspection is only for trench inspection. Excavator is on site and is currently digging nearby sewer. Electrical conduit has been installed and photos have been taken Phone #: ###-#### Inspection requested via web by John Harvey 2" service lateral and 1 1/4" feeder to garage rough in ok cover
Issue PAID IN FULL permit  4/9/2015 DONE
Payment received via Govolutions
Application received  4/9/2015 DONE
This permit was created on the web by John Harvey