Final | 6/24/2015 | 6/25/2015 | 6/25/2015 | A | PASS |
Eric Story
|
|
|
Steve Phone #: ###-#### corrections made final ok
|
Final | 6/23/2015 | 6/24/2015 | 6/24/2015 | A | FAIL |
Eric Story
|
|
|
Steve Phone #: ###-#### 210.8 all receptacles in a bath shall have GFCI protection 406.12 all recepts shallbe tamper resistant
|
Electrical Rough-In | 6/8/2015 | 6/8/2015 | 6/8/2015 | P | PASS |
Eric Story
|
|
|
Steve (homeowners brother) Phone #: ###-#### upstairs bath floor heat ok cover
|
Electrical Rough-In | 5/15/2015 | 5/18/2015 | 5/18/2015 | A | PASS |
Daryl DeGrange
|
|
|
Steve Phone #: ###-#### rough-in ok cover upstairs bathroom remodel
|
Electrical Rough-In | 5/15/2015 | 5/15/2015 | 5/15/2015 | P | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### complete all make-ups NEC 300.4 nail plate, shall not staple romex within 1 1/4in of edge of framing members
|
Application received | | | 4/16/2015 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 4/16/2015 | | DONE |
|
|
|
|