VOIDED CHANGE STATUS | | | 4/30/2015 | | DONE |
Rita DeYoung
|
|
|
This permit is in the County. All inspections Approved by the State.
|
Final | 4/29/2015 | 4/29/2015 | 4/29/2015 | P | FAIL |
Rock A. Hudson
|
|
|
The separate contractor hired by the homeowner to do the corrections cited by the inspector during the first EvenGreen rough in inspection has completed his work. The permit that he needed to pull and did not, has been filed properly and now finaled.
The inspection "fails" connected to this permit are not the work of EvenGreen Technology, nor were the inspections that failed requested by EvenGreen Technology. Our work has been passed with no issues by Boise City inspector, and this final is the only final that we have requested. Phone #: ###-#### Inspection requested via web by Ryan King Permit search does not show record of another permit by JDF Electric for repairs.
|
Final | 4/27/2015 | 4/27/2015 | 4/27/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Jim Phone #: ###-#### Permit does not exist at time of inspection for corrections of unsafe conditions. Called contractor told to pull permit for work performed.
|
Final | 4/21/2015 | 4/21/2015 | 4/21/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Solar Components Listing and inpection
Hey Guy''s -
Were finally back on track with this project. It started a couples months ago, but we couldn''t finish it before the customer left to Mexico for a month. My guys will be there to finish the second half of the array, with panels and inverters available for listing inspection on the ground. I''ll be there to install the knife switch and get the home run from the array to the sub panel installed. Phone #: ###-#### Inspection requested via web by Ryan King Although not part of this contractors scope of work life safety issues were noticed. BCC 4-05-32 Code violations not to be retained. 110.3 Electrical products shall be used as to its listing. 230.2- Circuits from 1 building shall not enter another structure with seperate service. well circuit shall originate form main house. LTFC NEC 356 shall be secured and fastened in place. not approved for overhead span. 230.22 over head conductors. Individual conductors shall be in a cable assembly or conduit. 680.21- Pool motors and equipment shall have GFCI protection.
|
Electrical Rough-In | 4/17/2015 | 4/21/2015 | 4/21/2015 | A | PASS |
Rock A. Hudson
|
|
|
Solar Components Listing and inpection
Hey Guy''s -
Were finally back on track with this project. It started a couples months ago, but we couldn''t finish it before the customer left to Mexico for a month. My guys will be there to finish the second half of the array, with panels and inverters available for listing inspection on the ground. I''ll be there to install the knife switch and get the home run from the array to the sub panel installed. Phone #: ###-#### Inspection requested via web by Ryan King Components all have listing approved for installation
|
Issue PAID IN FULL permit | | | 4/17/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/17/2015 | | |
|
|
|
|