Permit Information
Permit NumberELE15-01821
StatusFinaled
Name TREASURE VALLEY ELECTRIC INC
Site Address 2111 N CURTIS RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Wiring of addition
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/14/201510/15/201510/15/2015APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Steve Craig Final ok
Final10/5/201510/6/201510/6/2015AFAIL
DetailsRock A. Hudson
Inspection requested via web by Steve Craig 400.8- Wiring for split system. Flexible cords shall not be ran through walls or installed in a wall.
406.12- All 15 and 20 amp 120 volt receptacle outlets installed in a dwelling shall be tamper resistant type. Kit GFI and washer.
422.30- A disconnecting means shall be provided with in sight of water heater. 110.25- lock out acceptable.
No contact information provided
Electrical Rough-In6/24/20156/25/20156/25/2015APASS
DetailsDaryl DeGrange
Room to be remodeled and rewired is under a different permit. There are 2 permits for this job. Please call Steve at ###-#### with h questions Phone #: ###-#### Inspection requested via web by Steve Craig correction done, rough-in ok cover
Electrical Rough-In6/17/20156/18/20156/18/2015AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection request via web by Steve Craig 300.4- NM cable shall be protected from physical damage where ran thru notched or bored holes that do not maintain 1 1/4" from framing surface.
725.136- Low volt wiring for chime shall not accupy same box as power wiring.
Complete equipment grounding for sub panel.
Room between apartment and house not wired.
#2 Ser ran to sub panel check overcurrent.
Addition to 2109
Issue PAID IN FULL permit  6/17/2015 DONE
Payment received via Govolutions
Application received  6/17/2015 DONE
This permit was created on the web by Steve Craig