Final | 2/19/2016 | 2/22/2016 | 2/22/2016 | A | PASS |
Rex Boyles
|
|
|
Dennis Phone #: ###-#### correction made final ok
|
Final | 1/4/2016 | 1/4/2016 | 1/4/2016 | P | FAIL |
Eric Story
|
|
|
Dennis Phone #: ###-#### 210.12 all receptacles in a bedroom including smoke detectors shall have AFCI protection(smoke and outlet on closet wall not protected)
|
Electrical Rough-In | 10/21/2015 | 10/21/2015 | 10/21/2015 | P | CANC |
Rex Boyles
|
|
|
Dennis Phone #: ###-####
|
Electrical Rough-In | 10/19/2015 | 10/20/2015 | 10/20/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Dennis Phone #: ###-#### 210.52- Receptacle outlet shall be located with in 6' of a door opening, then with in 12' of previous receptacle. 334.30- NM cable shall be secured 1 1/4" from framing surface and shall not be stapled on edge.
|
Issue PAID IN FULL permit | | | 7/10/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
(F) Reprint permit | | | 7/10/2015 | | DONE |
|
|
|
|
Application received | | | 7/10/2015 | | |
|
|
|
|