Final | 9/30/2015 | 9/30/2015 | 9/30/2015 | P | PASS |
Rock A. Hudson
|
|
|
Back man door to garage is unlocked. Phone #: ###-#### Inspection requested via web by Kotton Corder Final ok
|
Final | 9/18/2015 | 9/18/2015 | 9/18/2015 | P | FAIL |
Rock A. Hudson
|
|
|
110.26- Works space, minimun of 30" wide and 36" deep shall be maintained for work space for pool panel. 680.21(C)- Outlets supplying pool pump motors shall be provided with GFCI protection. Unable to verify branch circuit feeding pool panel due to no answer at door.
|
Change Status to I | | | 9/18/2015 | | DONE |
|
|
|
finaled in error per Rock Hudson
|
Final | 9/16/2015 | 9/17/2015 | 9/17/2015 | A | PASS |
Rock A. Hudson
|
|
|
Final pool inspection Phone #: ###-#### Inspection requested via web by Kotton Corder Final ok
|
Electrical Rough-In | 8/25/2015 | 8/26/2015 | 8/26/2015 | A | PASS |
Rock A. Hudson
|
|
|
Underground bonding-pool Phone #: ###-#### Inspection requested via web by Kotton Corder Perimeter bond rough in ok cover
|
Electrical Rough-In | 8/6/2015 | 8/6/2015 | 8/6/2015 | A | PASS |
Rock A. Hudson
|
|
|
Underground Phone #: ###-#### Inspection requested via web by Kotton Corder Rough in ok cover
|
Electrical Rough-In | 7/28/2015 | 7/29/2015 | 7/29/2015 | A | PASS |
Rock A. Hudson
|
|
|
Pool underground and bonding Phone #: ###-#### Inspection requested via web by Kotton Corder Underground and 5 bonding point around perimeter of pool rough in ok cover
|
Issue PAID IN FULL permit | | | 7/28/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/28/2015 | | DONE |
|
|
|
This permit was created on the web by Kotton Corder
|