Final | 10/9/2015 | 10/9/2015 | 10/9/2015 | P | PASS |
Rock A. Hudson
|
|
|
Ron Phone #: ###-#### Unable to verify range cover due to gas range set in place. Wiring for electric range receptacle not landed at breaker. Final ok
|
Final | 10/7/2015 | 10/8/2015 | 10/8/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer 110.3(B)- Receptacles shall be installed to manufactured instructions. Reverse polarity front bed. 200.7- Grounded conductor used as ungrounded conductor shall be identified other than white at panel and AC disconnect. 210.8(A)(7)- Receptacle outlets installed with 6' of a sink shall have GFCI protection. 314.25- In complete installations each box shall have a cover. Range box. 352.30(A)- Service riser. PVC shall be secured within 3' of meter enclosure.
|
Rough-In Permanent Service | 8/4/2015 | 8/6/2015 | 8/6/2015 | P | CANC |
Eric Story
|
|
|
will not be ready till afternoon----call ron ###-#### Phone #: ###-#### Inspection requested via web by ron spen cer rough-in ok cover p/s u/g n ok
|
Issue PAID IN FULL permit | | | 8/4/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/4/2015 | | DONE |
|
|
|
This permit was created on the web by ron spen cer
|