Final | 12/1/2015 | 12/2/2015 | 12/2/2015 | P | PASS |
Rock A. Hudson
|
|
|
Damon Barr will be the electrician on site ###-#### Phone #: ###-#### Inspection requested via web by Liz Ramsey Closet luminaires chenged to florescent. Final ok
|
Final | 11/18/2015 | 11/19/2015 | 11/19/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Re-inspection for Habitat for Humanity, Contact Damonn. Phone #: ###-#### Inspection requested via web by Cathy Duchek 210.8- Receptacle outlets serving counter top in kitchen shall have GFCI protection. Unable to test due to trips as soon as load introduced. 350.30- LFMC shall be secured with in 12" of AC disconnect. 410.16- Luminaires located in closets shall have totally enclosed lamps and shall not be located with in 12" of shelves. Under stair and up closet. 440.22(C)- Overcurrent protection device shall ot exceed value on AC name plate. 30amp on 20 amp max
|
Final | 11/18/2015 | 11/18/2015 | 11/18/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Habitat for Humanity, Contact Damonn Phone #: ###-#### Inspection requested via web by Cathy Duchek AC, Furnace, transformer not complete. 406.12- All receptacle outlets installed in a residence shall be tamper resistant. All GFCI receptacles.
|
Electrical Rough-In | 9/16/2015 | 9/17/2015 | 9/17/2015 | A | PASS |
Bob Reichert
|
|
|
Rough-In Re-inspection. Contact Tom Betty Phone #: ###-#### Inspection requested via web by Cathy Duchek corrections made, ri ok
|
Permanent Service | 9/17/2015 | 9/17/2015 | 9/17/2015 | A | PASS |
Bob Reichert
|
|
|
Rough-In Re-inspection. Contact Tom Betty Phone #: ###-#### Inspection requested via web by Cathy Duchek p/s u/g n ok
|
Electrical Rough-In | 9/14/2015 | 9/14/2015 | 9/14/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Complete residential home wiring. Contact Tom Betty @ ###-#### Phone #: ###-#### Inspection requested via web by Cathy Duchek 110.3- Expansion joint in service riser shall be installed to manufacturers instructions. Shall be installed to allow movement in both directions. 210.52(G)(1)- At least 1 receptacle outlet shall be installed for each car bay. These receptacle outlets shall not feed outlets outside garage. 334.12- Check 12-2 NM cable, maybe installed where subfect to physical damage. Down hall under drywall nailer. Upstairs bed driven into staple under cable maybe damaged. 334.80- Where multiple NM cables pass through bored holes with out maintaining spacing allowable ampacity shall be adjusted. Above garage warm wall 12 and 10 current carrying conductors.
|
Issue PAID IN FULL permit | | | 9/14/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/14/2015 | | DONE |
|
|
|
This permit was created on the web by Cathy Duchek
|