Permit Information
Permit NumberELE15-02922
StatusFinaled
Name LEA ELECTRIC LLC
Site Address 1155 N FRAZIER PL
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation: Wire New House
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/1/201512/2/201512/2/2015PPASS
DetailsRock A. Hudson
Damon Barr will be the electrician on site ###-#### Phone #: ###-#### Inspection requested via web by Liz Ramsey Closet luminaires chenged to florescent. Final ok
Final11/18/201511/19/201511/19/2015PFAIL
DetailsRock A. Hudson
Re-inspection for Habitat for Humanity, Contact Damonn. Phone #: ###-#### Inspection requested via web by Cathy Duchek
210.8- Receptacle outlets serving counter top in kitchen shall have GFCI protection. Unable to test due to trips as soon as load introduced.
350.30- LFMC shall be secured with in 12" of AC disconnect.
410.16- Luminaires located in closets shall have totally enclosed lamps and shall not be located with in 12" of shelves. Under stair and up closet.
440.22(C)- Overcurrent protection device shall ot exceed value on AC name plate. 30amp on 20 amp max
Final11/18/201511/18/201511/18/2015PFAIL
DetailsRock A. Hudson
Habitat for Humanity, Contact Damonn Phone #: ###-#### Inspection requested via web by Cathy Duchek AC, Furnace, transformer not complete.
406.12- All receptacle outlets installed in a residence shall be tamper resistant. All GFCI receptacles.
Electrical Rough-In9/16/20159/17/20159/17/2015APASS
DetailsBob Reichert
Rough-In Re-inspection. Contact Tom Betty Phone #: ###-#### Inspection requested via web by Cathy Duchek corrections made, ri ok
Permanent Service9/17/20159/17/20159/17/2015APASS
DetailsBob Reichert
Rough-In Re-inspection. Contact Tom Betty Phone #: ###-#### Inspection requested via web by Cathy Duchek p/s u/g n ok
Electrical Rough-In9/14/20159/14/20159/14/2015PFAIL
DetailsRock A. Hudson
Complete residential home wiring. Contact Tom Betty @ ###-#### Phone #: ###-#### Inspection requested via web by Cathy Duchek 110.3- Expansion joint in service riser shall be installed to manufacturers instructions. Shall be installed to allow movement in both directions. 210.52(G)(1)- At least 1 receptacle outlet shall be installed for each car bay. These receptacle outlets shall not feed outlets outside garage. 334.12- Check 12-2 NM cable, maybe installed where subfect to physical damage. Down hall under drywall nailer. Upstairs bed driven into staple under cable maybe damaged. 334.80- Where multiple NM cables pass through bored holes with out maintaining spacing allowable ampacity shall be adjusted. Above garage warm wall 12 and 10 current carrying conductors.
Issue PAID IN FULL permit  9/14/2015 DONE
Payment received via Govolutions
Application received  9/14/2015 DONE
This permit was created on the web by Cathy Duchek