DOC - Permit Expired | 2/6/2019 | 2/6/2019 | 2/6/2019 | A | PASS |
Daryl DeGrange
|
|
|
No activity within 180 days. This permit is EXPIRED. A new permit is required to complete this job.
|
Permanent Service | 10/7/2015 | 10/8/2015 | 10/8/2015 | A | PASS |
Rock A. Hudson
|
|
|
Lockbox code 2630 Phone #: ###-#### Inspection requested via web by Eric Schroeder Circuit directory shall be completed for final. p/s u/g rec ok
|
Permanent Service | 9/22/2015 | 9/22/2015 | 9/22/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Lockbox access code: 2630. Please call Eric Schroeder ###-#### as you are headed that way. He would like to meet you there. Phone #: ###-#### Inspection requested via web by Eric Schroeder *For service reconnect grounding of service shall be up to present code requirements. 250.53(A)(2)- A single pipe grounding electrode shall be supplemented by an additional rod. 250.68(C)(1)- Underground interior metal water pipe shall be connected within 5' of point of entrance. 408.7- Unused circuit breaker openings shall be closed
|
Issue PAID IN FULL permit | | | 9/22/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/22/2015 | | DONE |
|
|
|
This permit was created on the web by Eric Schroeder
|