Final | 10/28/2015 | 10/28/2015 | 10/28/2015 | P | PASS |
Eric Story
|
|
|
call first for access, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER basement bedrooms final ok
|
Electrical Rough-In | 9/28/2015 | 9/28/2015 | 9/28/2015 | A | PASS |
Eric Story
|
|
|
call first Phone #: ###-#### Inspection requested via web by PAT MILLER basement rough-in ok cover
|
Electrical Rough-In | 9/24/2015 | 9/25/2015 | 9/25/2015 | A | FAIL |
Eric Story
|
|
|
Inspection requested via web by PAT MILLER 334.30 NM cable shall be supported within 12" of a box and supported every 4 1/2' and shall not be stapled on edge
|
Issue PAID IN FULL permit | | | 9/24/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/24/2015 | | DONE |
|
|
|
This permit was created on the web by PAT MILLER
|