Final | 12/10/2015 | 12/10/2015 | 12/10/2015 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
|
Final | 12/9/2015 | 12/9/2015 | 12/9/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 110.3- Electrical devices shall be connected as per manufacturers instructions. 202 kit GFCI not working, 202 3-way miss wire. 210.52(A)- A receptacle outlet shall be located with in 6' of back door. 101, 102 210.52(C)(1)- A receptacle outlet shall be located with in 24" of start of counter top between sink and wall. 201, 202
|
Rough-In Permanent Service | 10/7/2015 | 10/7/2015 | 10/7/2015 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 10/6/2015 | 10/6/2015 | 10/6/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 334.30- NM cable shall be secured with in 12" of a box and with in 4 1/2' of upper plate. 201 bed and 102 bath. * mudring missing of up bath 202
|
Issue PAID IN FULL permit | | | 10/4/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/4/2015 | | DONE |
|
|
|
This permit was created on the web by daniel bibikov
|
First Notice | 12/10/2015 | 12/10/2015 | | | |
Rock A. Hudson
|
|
|
|