Final | 1/22/2016 | 1/25/2016 | 1/25/2016 | A | PASS |
Rock A. Hudson
|
|
|
Garage code is 6767 Phone #: ###-#### Inspection requested via web by TOM BICANDI Final ok
|
Final | 1/21/2016 | 1/22/2016 | 1/22/2016 | A | FAIL |
Rock A. Hudson
|
|
|
Garage code is 6767 Phone #: ###-#### Inspection requested via web by TOM BICANDI 110.3- Breaker lockout shall be secured to overcurrent device as per manufacturers instructions. 314.21- Drywall shall be repaired around garage outlet and remove build up of mud so panel cover fits flush. 410.16(C)- Closet luminaire with incondscent lamp shall not be installed less than 12" from shelf. Up bed
|
Rough-In Permanent Service | 11/4/2015 | 11/4/2015 | 11/4/2015 | P | PASS |
Rock A. Hudson
|
|
|
Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 10/28/2015 | 10/29/2015 | 10/29/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI 110.3- NM cable has damaged insulation up bed front west. 300.4- NM cable shall be protected from physical damage where bored hole does not maintain 1 1/4" from framing surface. Up bed front east under switch.
|
Issue PAID IN FULL permit | | | 10/28/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/28/2015 | | DONE |
|
|
|
This permit was created on the web by TOM BICANDI
|