Final | 12/23/2015 | 12/24/2015 | 12/24/2015 | A | PASS |
Bob Reichert
|
|
|
Lockbox 4888, please call Jake with any questions, ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan ok final
|
Final | 12/23/2015 | 12/24/2015 | 12/24/2015 | A | PASS |
Bob Reichert
|
|
|
Lockbox 4888, please call Jake with any questions, ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan corrections made, ok final
|
Final | 12/22/2015 | 12/23/2015 | 12/23/2015 | A | FAIL |
Bob Reichert
|
|
|
Lockbox 4888. If you have any questions, please call Jake at ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan called, left correction notice, NEC 210.70(A) (2) (b) shall provide switched outside light at rear door of garage, 342.30(A) shall secure riser within 3' of panel
|
Permanent Service | 11/10/2015 | 11/12/2015 | 11/12/2015 | A | PASS |
Daryl DeGrange
|
|
|
If you have any questions, please call Jake ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan correction done, p/s o/h rec ok
|
Rough-In Permanent Service | 11/5/2015 | 11/6/2015 | 11/6/2015 | A | FAIL |
Rex Boyles
|
|
|
If you have any questions, please call Jake at ###-####, thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan grounding electrode conductor connected to rebar exposed to eliments (rust). 230.24-(A)ex.3- 18" minimum above roof to drip loop see exhibit 230.20 in hand book. (Power comp. can refuse to hook up)
|
Electrical Rough-In | 11/6/2015 | 11/6/2015 | 11/6/2015 | P | PASS |
Rex Boyles
|
|
|
If you have any questions, please call Jake at ###-####, thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan r/i ok
|
Issue PAID IN FULL permit | | | 11/5/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/5/2015 | | DONE |
|
|
|
This permit was created on the web by Clay Morgan
|