Final | 2/25/2016 | 2/26/2016 | 2/26/2016 | P | PASS |
Rock A. Hudson
|
|
|
Jonathon Phone #: ###-#### General contractor provided letter from Dutchboy Electric, Jonathan Poot owner stating taking responsibility for installation of floor heat system in master bathroom. Corrections made. Final ok
|
Final | 2/23/2016 | 2/24/2016 | 2/24/2016 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot BCC 4-05 15- Electrical installations shall be done be a electrical contractor or journeyman employed by contractor. Basement bath floor heat installed by tile installer. Need in writing contractor to take responsiblity for floor heat installation and GFCI protection. 410.16- Recessed closet luminaires shall have totally enclosed lamps. 422.30- Hard wired kitchen appliances shall have a disconnecting means. 110.25 lock outs acceptable. Called and left message.
|
Electrical Rough-In | 12/24/2015 | 12/28/2015 | 12/28/2015 | P | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot r/i ok upst. and dnst. Will install nailplates and staples as per our conversation
|
Issue PAID IN FULL permit | | | 12/3/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/3/2015 | | DONE |
|
|
|
This permit was created on the web by Jonathan Poot
|