Final | 2/19/2016 | 2/22/2016 | 2/22/2016 | A | PASS |
Bob Reichert
|
|
|
12 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs. And 280 watt SolarWorld panels, ETL listed.
A single home run, in metal conduit, is ran from the array to the knife switch, located next to meter base. From the knife switch to the breaker in the main panel located in the garage, at the bottom of the bussing, opposite the feeder lugs. The solar breaker and knife switch are permanently marked for solar with weather proof labels, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs down to the service ground.
The main panel is in the garage, so give the homeowner a call for access at 208.344.4012
Thanks guys, Ryan King Phone #: ###-#### Inspection requested via web by Ryan King ok final
|
Electrical Rough-In | 1/19/2016 | 1/19/2016 | 1/19/2016 | P | PASS |
Bob Reichert
|
|
|
listing inspection for panels and inverters. The crew will get to site about 11, and with only twelve panels, will only take about 4 hours. Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King listing for 12 panels and misc ok
|
Issue PAID IN FULL permit | | | 1/18/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/18/2016 | | DONE |
|
|
|
This permit was created on the web by Ryan King
|