Final | 3/29/2016 | 3/30/2016 | 3/30/2016 | A | PASS |
Rock A. Hudson
|
|
|
Garage code: 4200 Phone #: ###-#### Inspection requested via web by Will Sevy Final ok
|
Final | 3/25/2016 | 3/29/2016 | 3/29/2016 | A | FAIL |
Rock A. Hudson
|
|
|
garage code.....4200 Phone #: ###-#### Inspection requested via web by Will Sevy 110.3- Devices shall be wired as per manufacturers instructions. Hall 3-way. 314.20- Where box is mounted in combustible materials boxes shall be flush or an extension shall be installed. Outdoor outlets. 406.5- Receptacles shall be secured to box. Front outdoor receptacle. 410.16- Luminaire that can accept incandescent lamps shall not be installed less than 12" of shelf.
|
Rough-In Permanent Service | 2/11/2016 | 2/11/2016 | 2/11/2016 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Will Sevy Rough in ok cover p/s u/g n ok
|
Issue PAID IN FULL permit | | | 2/10/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/10/2016 | | DONE |
|
|
|
This permit was created on the web by Will Sevy
|