Final | 12/8/2016 | 12/9/2016 | 12/9/2016 | A | PASS |
Tom Saunders
|
|
|
Dennis Phone #: ###-####...
corrections made...ok to final
|
Final | 12/6/2016 | 12/7/2016 | 12/7/2016 | A | FAIL |
James Ady
|
|
|
Phone #: ###-#### 680.51(A) Submersible pumps Shall have GFCI protection. (Back Fountain) 406.12 A Tamper reasistant Receps shall be installed in dwelling units ( Kitchen Receps) 314.20 Boxes set back 1/4in shall have spark rings. ( KItchen back splash)
|
Electrical Rough-In | 6/27/2016 | 6/27/2016 | 6/27/2016 | P | PASS |
James Ady
|
|
|
Dennis Phone #: ###-#### Kitchen/ living only. rough in ok to cover
|
Issue PAID IN FULL permit | | | 6/13/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/13/2016 | | DONE |
|
|
|