DOC - Permit Expired | 2/14/2019 | 2/14/2019 | 2/14/2019 | A | PASS |
Daryl DeGrange
|
|
|
No activity within 180 days. This permit is EXPIRED. A new permit is required to complete this job.
|
Extend Permit 180 days | | 6/27/2018 | 6/27/2018 | | DONE |
Adele J Schaffeld-Griffin
|
|
|
|
Meeting | | | 6/27/2018 | | DONE |
Adele J Schaffeld-Griffin
|
|
|
Email sent 6/27/18
Marco, I have extended all 3 permits. Your new expiration date is December 10, 2018. You have been granted 3 extensions on your permits and per city ordinance no additional extensions shall be granted. You will need to have a required inspection on all of the permits prior to the extension date. Your permit expiration date will update with your inspection results.
Thank you
Adele Schaffeld-Griffin
Assistant Building Official
Planning and Development Services
Office: ###-####
aschaffeldgriffin@cityofboise.org
Making Boise the most livable city in the country.
|
ELE-Request for Extension | 12/15/2017 | 12/15/2017 | 12/15/2017 | A | DONE |
Adele J Schaffeld-Griffin
|
|
|
permit extension granted per applicant request 180 days
|
Extend Permit 180 days | | 12/15/2017 | 12/15/2017 | | DONE |
Adele J Schaffeld-Griffin
|
|
|
permit extention granted 180 days
|
Electrical Rough-In | 7/28/2017 | 7/28/2017 | 7/28/2017 | P | PASS |
Rock A. Hudson
|
|
|
Marco-radiant floors Phone #: ###-####-please call when your on your way Listing and class A GFCI protection at thermostat confirmed. Rough in ok cover
|
Extend Permit 180 days | | 6/19/2017 | 6/19/2017 | | DONE |
Jason Blais
|
|
|
|
ELE-Aging Inspection | 11/23/2016 | 11/25/2016 | 11/25/2016 | A | DONE |
Mark Moncarr
|
|
|
Marco Phone #: ###-#### Partial sheetrock cover
|
Electrical Rough-In | 9/23/2016 | 9/23/2016 | 9/23/2016 | P | PASS |
Mark Moncarr
|
|
|
Marco Phone #: ###-#### ok cover
|
Electrical Rough-In | 9/20/2016 | 9/20/2016 | 9/20/2016 | P | FAIL |
Mark Moncarr
|
|
|
would like call ahead; Marco Phone #: ###-#### boxes need changed out due to box fill, need connectors for wires entering cans, wires need stapled every 4-1/2', boxes need made up to ensure ground wire connection
|
Electrical Rough-In | 9/19/2016 | 9/19/2016 | 9/19/2016 | P | NH |
Mark Moncarr
|
|
|
Marco Phone #: ###-####
|
Conference | 8/8/2016 | 8/8/2016 | 8/8/2016 | P | DONE |
James Ady
|
|
|
call Marco 1/2 hour prior to going out. Phone #: ###-#### Talked about 6 and 12 rule for outlet spaceing, need for GFCI protection in bathroom AFCI Prtection in bedroom, GFCI protection on floor heat, Tamper resistant receps, and inspection on floor heat before covering
|
Application received | | | 6/21/2016 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 6/21/2016 | | DONE |
|
|
|
|