Final | 3/17/2017 | 3/20/2017 | 3/20/2017 | P | PASS |
Eric Story
|
|
|
James Phone #: ###-#### Final ok
|
Final | 3/17/2017 | 3/20/2017 | 3/20/2017 | A | PASS |
Eric Story
|
|
|
James Phone #: ###-#### Correction fixed final ok
|
Final | 3/10/2017 | 3/13/2017 | 3/13/2017 | P | CANC |
James Ady
|
|
|
Jen Phone #: ###-####
|
Final | 3/9/2017 | 3/10/2017 | 3/10/2017 | A | CANC |
Eric Story
|
|
|
James Phone #: ###-####
|
Final | 3/6/2017 | 3/8/2017 | 3/8/2017 | A | FAIL |
Eric Story
|
|
|
james Phone #: ###-#### 210.12 all lights and receptacles shall be AFCI protection 410.16(b) all lights in a closet shall be totally enclosed
|
Electrical Rough-In | 9/29/2016 | 9/29/2016 | 9/29/2016 | P | PASS |
James Ady
|
|
|
James// please call ahead Phone #: ###-#### Corrections made rough in ok
|
Electrical Rough-In | 9/26/2016 | 9/28/2016 | 9/28/2016 | P | FAIL |
Daryl DeGrange
|
|
|
James` Phone #: ###-#### Securing within 12 in. panel, within 1 1/4 of edge of framing members, abrasion protection recessed cans, bath fan, replace damaged NM from missed hammer blows
|
Conference | 8/4/2016 | 8/5/2016 | 8/5/2016 | P | DONE |
Rock A. Hudson
|
|
|
James Phone #: ###-#### Discussed flipping panel around in wall and will be in dining area. Master bed and bath addition talked receptacle spacing, tamper resistant type, bathroom recept.20 amp dedicated, light over shower wet location rated, outdoor recept type and cover.
|
Issue PAID IN FULL permit | | | 8/4/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/4/2016 | | DONE |
|
|
|
This permit was created on the web by James Orr
|