Final | 7/2/2017 | 7/3/2017 | 7/3/2017 | P | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by cris flores Ok final. Contractor is going to remove 2 pole 20a and replace with panel blanks. Power will be disconnected to dryer/blower in downstairs bath.
|
Final | 6/30/2017 | 6/30/2017 | 6/30/2017 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by cris flores 110.3- Box noted in master shower is for equipmant to be mounted in shower, when asked for instructions for listing for wet locations contractor stated all power to box has been disconnected and he refused to install in location. 110.3- GFCI protection shall be provided as per manufacturers instructions for bath fan installed in shower. 210.52(C)- Area around nook built in table has counter space that shall have receptacle outlet adjacent to counter. 1 side exposed, need additional for left side if facing table. 314.16- Box mounted in pull out for receptacle shall be of sufficient size for wiring and device. 11.25 cubic inches minimum. 404.9- All face plates shall be installed to completely enclose boxes. switches in garage and misc else where. 422.16- Flexible cord for disposal shall be installed to verify length.. Class A GFCI protection for floor heat has been verified on thermostats. Caution female owner being very difficult.
|
Electrical Rough-In | 6/15/2017 | 6/15/2017 | 6/15/2017 | P | PASS |
Eric Story
|
|
|
Remainig walls in garage ok cover as well
|
Rough-In Permanent Service | 6/14/2017 | 6/15/2017 | 6/15/2017 | A | CANC |
Eric Story
|
|
|
Inspection requested via web by cris flores No rough-in at this time just p/s
|
Permanent Service | 6/15/2017 | 6/15/2017 | 6/15/2017 | P | PASS |
Eric Story
|
|
|
Inspection requested via web by cris flores Correction fixed p/s u/g n ok
|
Rough-In Permanent Service | 6/12/2017 | 6/14/2017 | 6/14/2017 | P | FAIL |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by cris flores Grounds and neutrals shall be seperated Group disc
|
Electrical Rough-In | 3/3/2017 | 3/3/2017 | 3/3/2017 | A | PASS |
Mark Moncarr
|
|
|
heat floor inspection Phone #: ###-#### Inspection requested via web by cris flores floorheat ok cover
|
Electrical Rough-In | 1/4/2017 | 1/5/2017 | 1/5/2017 | P | PASS |
Mark Moncarr
|
|
|
Wall cover in the bath/pantry Phone #: ###-#### Inspection requested via web by cris flores cover ok. Need manufacturer specs for Tornado wall dryer. Needs to be approved for wet location.
|
Electrical Rough-In | 1/4/2017 | 1/4/2017 | 1/4/2017 | P | CANC |
Rock A. Hudson
|
|
|
Wall cover in bath/pantry Phone #: ###-#### Inspection requested via web by cris flores Called contact area job is located is not accessible due to weather conditions. Left message to recall when accessible.
|
Electrical Rough-In | 12/27/2016 | 12/28/2016 | 12/28/2016 | A | PASS |
Eric Story
|
|
|
Partial inspection in Office, living room, and laundry room Phone #: ###-#### Inspection requested via web by cris flores Office,entertainment and laundry ok cover, Contractor will move panel in garage due to being installed in warm wall
|
Electrical Rough-In | 12/21/2016 | 12/21/2016 | 12/21/2016 | P | FAIL |
Rock A. Hudson
|
|
|
Office area has been changed and wiring incomplete. Area not approved for cover. Contractor will call when ready.
|
Electrical Rough-In | 12/5/2016 | 12/6/2016 | 12/6/2016 | A | PASS |
Rock A. Hudson
|
|
|
Office only Inspection requested via web by cris flores Office only rough in ok cover
|
Electrical Rough-In | 11/3/2016 | 11/4/2016 | 11/4/2016 | A | PASS |
Mark Moncarr
|
|
|
Wall cover and ceiling Phone #: ###-#### Inspection requested via web by cris flores 3 boxes to be changed due to box fill, 1 in ceiling and 2 on wall directly below. Needs to be done upon final
|
Electrical Rough-In | 10/13/2016 | 10/14/2016 | 10/14/2016 | A | PASS |
Rock A. Hudson
|
|
|
Partial wall and ceiling cover Phone #: ###-#### Inspection requested via web by cris flores 1st floor nook and family room walls and ceilings rough in ok cover
|
Issue PAID IN FULL permit | | | 10/13/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/13/2016 | | DONE |
|
|
|
This permit was created on the web by cris flores
|