Final | 1/30/2017 | 1/30/2017 | 1/31/2017 | P | PART |
James Ady
|
|
|
Code is 2010 Phone #: ###-#### Inspection requested via web by Jason Wicks corrections made final ok
|
Final | 1/27/2017 | 1/27/2017 | 1/27/2017 | P | FAIL |
James Ady
|
|
|
Requesting final on house, the ground is frozen so we can not trench to the back shed for power yet. Code to get into house is 2010 Phone #: ###-#### Inspection requested via web by Jason Wicks 210.8 A 2 All Garage receps shall be GFCI Protected. ( Vac ) 110.3 B Listed equipment shall installed as per manufacturers instruction. (Garage man door gfci double protected) 406.12 A All dwelling receps shall be tamper resistant.(up washer GFCI) 404.9 A All switches shall have faceplates. (Closet next to bar)
|
Electrical Rough-In | 11/21/2016 | 11/21/2016 | 11/21/2016 | P | CANC |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks needed perm serv also
|
Rough-In Permanent Service | 11/21/2016 | 11/21/2016 | 11/21/2016 | P | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Rough in ok p/s u/g n ok
|
Issue PAID IN FULL permit | | | 11/21/2016 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/21/2016 | | DONE |
|
|
|
This permit was created on the web by Jason Wicks
|