Permit Information
Permit NumberELE16-03830
StatusFinaled
Name BURKE ELECTRICAL CONTRACTING
Site Address 228 E CRESTLINE DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Remodel basement
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/9/20173/10/20173/10/2017APASS
DetailsMark Moncarr
Please call 20 min before arrival. Thanks Phone #: ###-#### Inspection requested via web by Kevin Burke Ok final
Electrical Rough-In11/23/201611/23/201611/23/2016AFAIL
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Kevin Burke Ok to cover roughed in rooms. Disconnect is needed outside under meter location for the panel inside. 230.70, also Boise City Ordinance 4-05-31(C) unfused conductors entering structure cannot be longer than 4'. Re-establish grounding at disconnect, and seperate grounds and neutrals in house panel along with pulling bond screw.
Issue PAID IN FULL permit  11/23/2016 DONE
Payment received via Govolutions
Application received  11/23/2016 DONE
This permit was created on the web by Kevin Burke