Final | 6/12/2017 | 6/13/2017 | 6/13/2017 | A | PASS |
James Ady
|
|
|
Bob Phone #: ###-#### Corrections made Final ok
|
Final | 6/6/2017 | 6/7/2017 | 6/7/2017 | A | FAIL |
James Ady
|
|
|
Bob Phone #: ###-#### 440.22C. A/C overcurrent protection shall not exceed nameplate rating. 406.12A All dwelling unit receps shall be tamper resistant.(Kitchen and Bath GFCI receps) Missing lights in bed and Back patio. Out door recep by A/C Dead. 410.12 Closet Storage space. Lights shall not be installed within 12in of edge of shelf. Strap liquidtight below A/C with listed straps
|
Electrical Rough-In | 3/27/2017 | 3/28/2017 | 3/28/2017 | P | CANC |
James Ady
|
|
|
Bob Phone #: ###-#### Needed perm serv also
|
Rough-In Permanent Service | 3/28/2017 | 3/28/2017 | 3/28/2017 | P | PASS |
James Ady
|
|
|
Bob Phone #: ###-#### rough in ok p/s o/h n ok
|
Electrical Rough-In | 3/22/2017 | 3/23/2017 | 3/23/2017 | P | NR |
James Ady
|
|
|
Bob Phone #: ###-#### needed confer.
|
Conference | 3/23/2017 | 3/23/2017 | 3/23/2017 | P | DONE |
James Ady
|
|
|
Bob Phone #: ###-#### Talked about required kitchen Counter receps, Wall spacing, Required Bath, Laundry and kitchen small appliance circuits.
|
(F) Reprint permit | | | 3/6/2017 | | DONE |
|
|
|
|
Application received | | | 12/8/2016 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 12/8/2016 | | DONE |
|
|
|
|