Permit Information
Permit NumberELE17-00013
StatusFinaled
Name D C ELECTRICAL SOLUTIONS
Site Address 3948 E PARKCENTER BLVD
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/1/20173/1/20173/1/2017PPASS
DetailsJames Ady
garage code 1001 Phone #: ###-#### Inspection requested via web by Charles Davis corrections made final ok
Final2/28/20172/28/20172/28/2017PFAIL
DetailsJames Ady
garage code 1001 Phone #: ###-#### Inspection requested via web by Charles Davis 210.8 A 3 All outdoor receps shall be GFCi protected. ( recep by panel) 110.3 B Listed equipment Shall be installed per man specs. (front WP recep.) 406.9 B 1 Outdoor receps shall be weather resistant.( front WP recep) 334.12 NM cable shall not be exposed. ( romex above range hood)
Final1/13/20171/17/20171/13/2017ACANC
DetailsJames Ady
garage code 1001 Phone #: ###-#### >> Inspection requested via web by Charles Davis Inspection cancelled from web by: Charles Davis
Rough-In Permanent Service1/5/20171/6/20171/6/2017APASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Charles Davis rough in ok p/s u/g n ok
Rough-In Permanent Service1/3/20171/5/20171/5/2017ANH
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Charles Davis No access. Too much snow. Foam seal ok No Cover. Recall rough in inspection
Issue PAID IN FULL permit  1/3/2017 DONE
Payment received via Govolutions
Application received  1/3/2017 DONE
This permit was created on the web by Charles Davis