Final | 5/5/2017 | 5/8/2017 | 5/8/2017 | P | PASS |
Rock A. Hudson
|
|
|
Final Inspection on ADA Units 811 and 813 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek All units done. Final ok
|
Final | 5/4/2017 | 5/5/2017 | 5/5/2017 | P | PART |
Rock A. Hudson
|
|
|
Final inspection on building 7 and ADA unit 1013 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek BLDG and unit noted TCO OK
|
Final | 5/2/2017 | 5/3/2017 | 5/3/2017 | A | PART |
Rock A. Hudson
|
|
|
Final for Units 513 and 613 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Rooms noted TCO OK
|
Final | 5/2/2017 | 5/2/2017 | 5/2/2017 | P | PART |
Rock A. Hudson
|
|
|
Final on Building 8 excluding 811 and 813. Contact Dan Hutchinson Phone #: ###-#### Inspection requested via web by Cathy Duchek Rooms noted not ready rest TCO OK
|
Final | 4/27/2017 | 4/28/2017 | 4/28/2017 | P | PART |
Rock A. Hudson
|
|
|
Final on Building 8 and Final on Building 4 units 411 and 413. Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Building 8 some GFCI devices not tamper resistant. 406.12(B)- All 15 and 20 amp 120 volt receptacle outlets shall be tamper resistant type 411 and 413 only TCO ok
|
Electrical Rough-In | 4/24/2017 | 4/24/2017 | 4/24/2017 | P | PASS |
Rock A. Hudson
|
|
|
Ceiling Rough in Inspection for Building 7 Contact Dan Hutchinson @ ###-#### or ###-#### Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek BLDG 7 all units rough in ok cover
|
Electrical Rough-In | 4/19/2017 | 4/20/2017 | 4/20/2017 | A | PASS |
Rock A. Hudson
|
|
|
Rough-In Inspection for units 811 ; 813 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek Area noted rough in ok cover
|
Final | 4/18/2017 | 4/19/2017 | 4/19/2017 | P | PART |
Rock A. Hudson
|
|
|
Final Inspection for Building 14. Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek Junction box removed in 1411. TCO OK
|
Final | 4/14/2017 | 4/17/2017 | 4/17/2017 | P | PART |
Rock A. Hudson
|
|
|
Final for Building 12 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek 406.12 ex.2- Receptacles that are part of a luminare not required to be tamper resistant. Luminaire, swithes, and receptacles all mounted on back plate. TCO building 12 ok
|
Final | 4/13/2017 | 4/14/2017 | 4/14/2017 | P | FAIL |
Eric Story
|
|
|
Final Inspection for Building 12 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek 406 Tamper resistant required for all 120v receptacles
|
Electrical Rough-In | 4/13/2017 | 4/14/2017 | 4/14/2017 | P | PASS |
Eric Story
|
|
|
Rough-In Inspection on Building 8 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Building 8 minus ADA rooms ok cover
|
Electrical Rough-In | 4/10/2017 | 4/10/2017 | 4/10/2017 | A | PASS |
Rock A. Hudson
|
|
|
Rough In Inspection on Building #14 Contact Dan Hutchinson Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Check on final 1411 junction box in ceiling in front of panel, ground splice out of box and wrong color. Rough in ok cover
|
Electrical Rough-In | 4/5/2017 | 4/6/2017 | 4/6/2017 | P | PASS |
Rock A. Hudson
|
|
|
Rough in inspection for Building 12 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Rough in ok cover
|
Electrical Rough-In | 4/5/2017 | 4/5/2017 | 4/5/2017 | P | CANC |
Rock A. Hudson
|
|
|
Rough-In inspection for Building 12 Contact Dan Hutchinson Thank you Phone #: ###-#### >> Inspection requested via web by Cathy Duchek Inspection cancelled from web by: Cathy Duchek
|
Final | 4/4/2017 | 4/5/2017 | 4/5/2017 | A | PART |
Rock A. Hudson
|
|
|
Final Inspection on Building 11 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek 622, 623, bldg 11 TCO ok
|
Final | 3/29/2017 | 3/30/2017 | 3/30/2017 | A | PART |
Rock A. Hudson
|
|
|
Final Inspection for Building 10 Contact Dan Hutchinson Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek 1013 not ready, rest TCO ok
|
Electrical Rough-In | 3/29/2017 | 3/30/2017 | 3/30/2017 | A | PASS |
Rock A. Hudson
|
|
|
Rough In Inspection for unit #513 Contact Dan Hutchinson. Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Room noted rough in ok cover
|
Electrical Rough-In | 3/27/2017 | 3/28/2017 | 3/28/2017 | A | PASS |
Rock A. Hudson
|
|
|
Rough-In Inspection for Handicap units 613 and 1013. Contact Dan Hutchinson Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek check fusing on bath receptacle 15 amp on final. Rooms noted rough in ok cover
|
Electrical Rough-In | 3/22/2017 | 3/23/2017 | 3/23/2017 | A | PASS |
James Ady
|
|
|
Final inspection for Building 9 and Rough-In inspection for Building 11 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek Buildin 9 final ok. Building 11 Rough in ok, Units 622,623 Still need finaled. 613 Still needs Rough in.
|
Final | 3/16/2017 | 3/17/2017 | 3/17/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Final inspection for building 9 and final inspection for units 622, and 623. Contact Dan Hutchinson Phone #: ###-#### Inspection requested via web by Cathy Duchek 622- Water heater lockout needed, 623- lockout on wrong breaker needed WH. Building 9 not ready DW missing and floor receptacles not trimmed.
|
Electrical Rough-In | 3/16/2017 | 3/16/2017 | 3/16/2017 | A | PASS |
Rock A. Hudson
|
|
|
Building 10 Rough-in inspection Contact Dan Hutchinson Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek 1013 not ready, rest of bldg 10 rough in ok cover
|
Final | 3/10/2017 | 3/10/2017 | 3/10/2017 | P | PART |
James Ady
|
|
|
Building #6 final Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek 613 not ready, 624 missing floorbox cover, 622 Up Bath GFCI and up bath lights in-op. Partial final on all other units ok
|
Electrical Rough-In | 3/9/2017 | 3/10/2017 | 3/10/2017 | P | PASS |
James Ady
|
|
|
Rough-In Inspection for Building #9 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Micro Recep and paddle fan add rough in ok
|
Final | 3/2/2017 | 3/3/2017 | 3/3/2017 | P | PART |
Rock A. Hudson
|
|
|
Final Inspection for Building #5 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek 513 excluded, rest of building 5 TCO ok.
|
Electrical Rough-In | 2/28/2017 | 3/1/2017 | 3/1/2017 | A | PART |
Rock A. Hudson
|
|
|
Rough-In Inspection on Building #6. Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek 613 not ready. Paddle fan boxes installed, splice kits used for bath fans listed and installed correctly. Rest of bldg 6 rough in ok cover
|
Final | 2/27/2017 | 2/27/2017 | 2/27/2017 | P | PART |
Rock A. Hudson
|
|
|
Final Inspection for Building #4 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek 411, 413 not ready... rest TCO ok
|
Final | 2/23/2017 | 2/24/2017 | 2/24/2017 | P | FAIL |
Rock A. Hudson
|
|
|
Final Inspection for Six (6) non-ADA units in Building #5 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek Wrong building noted wanted BLDG #4. Created rough in for 411 and 413. 422.30- Lockout for water heaters required in all units not within sight of panel. 300.15- Unit 422 missing cover plates.
|
Electrical Rough-In | 2/24/2017 | 2/24/2017 | 2/24/2017 | P | PASS |
Rock A. Hudson
|
|
|
Final Inspection for Six (6) non-ADA units in Building #5 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek Units 411, 413 not to be advertised as ADA units so not required to be ADA compliant. Units noted rough in ok cover
|
Electrical Rough-In | 2/21/2017 | 2/22/2017 | 2/22/2017 | P | PART |
Rock A. Hudson
|
|
|
Rough-in Inspection for Residence Inn Building #5 Contact Dan Hutchinson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek ADA unit not ready, paddle fan wiring and box install not done, bath fan change out not done. Bath fans and paddle fans OK to complete with out inspections. All but ADA unit rough in ok cover
|
Electrical Rough-In | 2/15/2017 | 2/16/2017 | 2/16/2017 | A | PASS |
Rock A. Hudson
|
|
|
Rough-In Building #4 Contact Dan Hutchinson Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek Building 4 except units 411, 413 ADA units. J-box above panel due to damaged wire in 433. Fans done. Others rough in ok cover
|
Final | 2/14/2017 | 2/14/2017 | 2/14/2017 | P | PART |
Rock A. Hudson
|
|
|
Final Inspection for Building #3 Contact Cesar Salcedo Phone #: ###-#### Inspection requested via web by Cathy Duchek Building #3 TCO OK
|
Final | 2/8/2017 | 2/9/2017 | 2/9/2017 | A | PART |
Rock A. Hudson
|
|
|
Final Inspection for Building #2 Contact Cesar Salcedo Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek TCO building #2 temp final ok
|
Final | 2/3/2017 | 2/3/2017 | 2/3/2017 | P | PART |
Rock A. Hudson
|
|
|
Final Inspection for Building #1 Contact Cesar Salcedo Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek TCO for building 1 ok
|
Final | 1/31/2017 | 2/3/2017 | 2/3/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Final Inspection for Building #1 AM Inspection preferred Contact Cesar Salcedo Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek 210.8- All 15 or 20 amp receptacle outlets located within 6' of a sink shall have GFCI protection. All units. 406.12- All 15 and 20 amp receptacle outlets shall be tamper resistant type. Receptacle built into stair light. 124. 422.30- A means shall be provided to disconnect water heater power shall be within sight of unit. 110.25- lockout acceptable.
|
Conference | 2/1/2017 | 2/2/2017 | 2/2/2017 | A | DONE |
Rock A. Hudson
|
|
|
Consultation for Building #1 Contact Cesar Salcedo. Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek Contractor wanted to check for approval on receptacle outlets each side of bed. The units are guest rooms. As per 210.60(B)- receptacles shall be located so attachment plug will not be in contact with bed furniture. They will install a junction box behind removeable headboard and move receptacle where needed.
|
Final | 1/26/2017 | 1/27/2017 | 1/27/2017 | P | CANC |
Eric Story
|
|
|
Check ceilng fan boxes on bld 2@3 NO final just Rough-in
|
Electrical Rough-In | 1/27/2017 | 1/27/2017 | 1/27/2017 | P | PASS |
Eric Story
|
|
|
Check ceilng fan boxes on bld 2@3 Verified u/l listing fan boxes being used to support paddle fans
|
Electrical Rough-In | 1/25/2017 | 1/26/2017 | 1/26/2017 | A | PASS |
Eric Story
|
|
|
Building 3 Rough-In Contact Cesar Salcedo Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Building 3 circuits added for micro ok cover
|
Electrical Rough-In | 1/20/2017 | 1/23/2017 | 1/23/2017 | A | PASS |
Eric Story
|
|
|
Rough-In Wall Inspection Building 2 Contact Cesar Salcedo ###-#### Phone #: ###-#### Inspection requested via web by Cathy Duchek Issue with paddel fan without boxes and non compliant wiring with be resolved with proper methods. Building 2 addition for micro ok cover
|
Electrical Rough-In | 1/11/2017 | 1/18/2017 | 1/18/2017 | A | DONE |
Rock A. Hudson
|
|
|
Tom ###-#### Check temp wiring on club house to sign. Temp wiring has been removed. Thank You
|
Electrical Rough-In | 1/13/2017 | 1/17/2017 | 1/17/2017 | A | PASS |
Rock A. Hudson
|
|
|
Rough-in Inspection. Contact Cesar Salcedo Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Temp power issue on ELE16-04108 gate house. To still check paddle fan boxes on 2nd floor. Addition of microwave circuit on all 8 units for building 1 rough in ok cover
|
Conference | 1/9/2017 | 1/11/2017 | 1/12/2017 | A | DONE |
Rock A. Hudson
|
|
|
Consult about new code requirements in old building. Contact Tom Betty. Phone #: ###-#### Inspection requested via web by Cathy Duchek Discussed electrical requirements of remodel. Walls will not have drywall removed will be repainted. Patches will be created to add microwave circuits. Surface mounted conduits shall be listed assembly, receptacles shall be tamper resistant type, range receptacles shall be 4 wire, bedroom areas not required to be AFCI protected due to no new wiring being installed, check with Building inspector on ADA requirements for units that may be marketed as ADA. Panels may need lowered to comply. Temp wiring feeding sign not compliant, GFCI protection, installed by unlicensed person, shall repair with in 5 working days. Will schedule reinspect for temp wiring for Wed. 1-18-17.
|
Issue PAID IN FULL permit | | | 1/9/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/9/2017 | | DONE |
|
|
|
This permit was created on the web by Cathy Duchek
|
First Notice | 5/8/2017 | 5/8/2017 | | | |
Rock A. Hudson
|
|
|
|