Final | 6/28/2017 | 6/29/2017 | 6/29/2017 | A | PASS |
Eric Story
|
|
|
code 8199 Phone #: ###-#### Inspection requested via web by Neal Rumsey Corrections fixed final ok
|
Final | 6/27/2017 | 6/28/2017 | 6/28/2017 | A | FAIL |
Tom Saunders
|
|
|
code 8199 Phone #: ###-#### Inspection requested via web by Neal Rumsey...
1. missing plate on switches at fireplace 2. all bath outlets shall have GFI protection...outlets within 6ft of sink shall have GFI protection...outlet down low in mst bath 3. exposed romex shall have protection from physical damage...under kitchen sink 4. D/W shall be hooked up and operational 5. OCPD on A/C is to large
|
Electrical Rough-In | 4/10/2017 | 4/11/2017 | 4/11/2017 | A | PASS |
Rock A. Hudson
|
|
|
Floor Heat in the master Phone #: ###-#### Inspection requested via web by Neal Rumsey Rough in ok cover
|
Rough-In Permanent Service | 1/31/2017 | 1/31/2017 | 1/31/2017 | P | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey....
rough ok to cover p/s o/h rec ok
|
Issue PAID IN FULL permit | | | 1/24/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/24/2017 | | DONE |
|
|
|
This permit was created on the web by Neal Rumsey
|