Final | 4/24/2017 | 4/25/2017 | 4/25/2017 | A | PASS |
Eric Story
|
|
|
Chris Phone #: ###-#### Corrections fixed final ok
|
Final | 4/18/2017 | 4/19/2017 | 4/19/2017 | A | FAIL |
Eric Story
|
|
|
Chris Phone #: ###-#### 314.20 Spark ring required when box is not flush with tile 422.30 Lockable disc for dishwasher
|
Electrical Rough-In | 2/15/2017 | 2/15/2017 | 2/15/2017 | P | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot Corrections fixed rough-in ok cover
|
Electrical Rough-In | 2/14/2017 | 2/15/2017 | 2/15/2017 | A | FAIL |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot Bushings needed for exhaust fans Wall spacing greater then 2 foot need receptacles in beds and not more then 6 foot from door openings Shall maintain 1/4 of romex in boxes
|
Issue PAID IN FULL permit | | | 2/13/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/13/2017 | | DONE |
|
|
|
This permit was created on the web by Jonathan Poot
|