Print Statement | | | 7/30/2018 | | DONE |
|
|
|
|
First Notice | 4/7/2017 | 4/7/2017 | 7/5/2017 | | DONE |
Eric Story
|
|
|
This permit finaled on the web by Sean DeLacy
|
Final | 4/6/2017 | 4/7/2017 | 4/7/2017 | A | PASS |
Eric Story
|
|
|
Randy is the onsite contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Final ok
|
Permanent Service | 2/20/2017 | 2/21/2017 | 2/21/2017 | A | PASS |
Rock A. Hudson
|
|
|
Randy is the onsite contact. Phone #: ###-#### Inspection requested via web by Buster Bowen p/s o/h n ok
|
Permanent Service | 2/16/2017 | 2/17/2017 | 2/17/2017 | P | FAIL |
Rock A. Hudson
|
|
|
Randy is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen BCC 4-05-31- Unfused conductor shall not be ran on interior of walls. from meter base ran on interior of wall 7' to main breaker panel. 110.24- Available fault current shall be posted prior to permanent service inspection.
|
Electrical Rough-In | 2/16/2017 | 2/17/2017 | 2/17/2017 | P | PASS |
Rock A. Hudson
|
|
|
wall Cover. Randy is the onsite contact Phone #: ###-#### Inspection requested via web by Buster Bowen Will check for labels on future solar conduits when permanent service inspection is done. Walls and hardlid rough in ok cover
|
Issue PAID IN FULL permit | | | 2/16/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/16/2017 | | DONE |
|
|
|
This permit was created on the web by Buster Bowen
|