Final | 10/19/2017 | 10/24/2017 | 10/24/2017 | A | PASS |
Rock A. Hudson
|
|
|
Clayton Phone #: ###-#### Job reduced to bathroom only. New permit to be pulled for bedroom and mud room. Final ok
|
Electrical Rough-In | 3/6/2017 | 3/6/2017 | 3/6/2017 | P | PASS |
Tom Saunders
|
|
|
Clay Phone #: ###-####...
rough in master bath ok to cover
|
Conference | 2/16/2017 | 2/23/2017 | 2/23/2017 | A | DONE |
Rock A. Hudson
|
|
|
Clayton Phone #: ###-#### Remodel of old garage turned into a bonus room. Changing room into a bed and bathroom. Discussed required 20 amp GFCI circuit for bathroom receptacles, lighting in bath can be on 20 amp if it does not leave bath. Wet location rating of recessed light over shower. Required lighting outlets for bedroom. Minimum receptacles required for new walls in bedroom. Tamper resistant all new receptacles and AFCI for all bed outlets. Lights, switches, receptacles, and CO, smokes.
|
Application received | | | 2/16/2017 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 2/16/2017 | | DONE |
|
|
|
|