Permit NumberELE17-00753
StatusFinaled
Name HUMPHREYS JOHN E &
Site Address 303 W HOWE ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Replacing old wire, breakers, outlets, and switches.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/9/20177/10/20177/10/2017APASS
DetailsJames Ady
Please call 5-10 minutes before arriving. I am only 3 miles away from the property. Thanks! Phone #: ###-#### Inspection requested via web by John Humphreys Final ok
Electrical Rough-In5/14/20175/15/20175/15/2017APASS
DetailsJames Ady
Inspection requested via web by John Humphreys Back wall Rough in ok to cover
Electrical Rough-In4/27/20174/28/20174/28/2017PPASS
DetailsJames Ady
I''m only 3-4 miles from property. Please call 10 minutes before so I can open the house. If AM inspection is more convenient for inspector, please call, as I may be available. Phone #: ###-#### Inspection requested via web by John Humphreys Bed wall behind panel needs re-inspected. Rest of house ok to cover
Conference4/27/20174/27/20174/27/2017PDONE
DetailsJames Ady
Just need clarification on a couple of things Phone #: ###-#### Inspection requested via web by John Humphreys Add recep on 2ft wall in bedroom, 3 wire between smoke detectors, No lights on appliance circuit( Above sink), Make up all boxes and tie Nuetrals to gether in switches, Put covers on can junction boxes, New home run for Kitchen GFCI, 18-2 for openers and chime
Electrical Rough-In4/24/20174/24/20174/24/2017PPASS
DetailsMark Moncarr
Please call 10 minutes before inspection so I can meet inspector at property with a key to get in. Phone #: ###-#### Inspection requested via web by John Humphreys Ok cover all walls except kitchen. Feed sink light of kitchen lighting circuit, not dishwasher/disposal circuit. Add 1 outlet to right of sink. Outlet might be at 26-27", ok if within a few inches of the 24" rule.
Electrical Rough-In4/3/20174/4/20174/4/2017APASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by John Humphreys west garage wall only ( Behind furnace and washer/dryer)
Final3/23/20173/24/20173/24/2017PNR
DetailsJames Ady
John Phone #: ###-####
Conference3/24/20173/24/20173/24/2017PDONE
DetailsJames Ady
discussed recep lay out in bed living and kitchen, ark fault, gfci and garage requirements
Issue PAID IN FULL permit  3/22/2017 DONE
Payment received via Govolutions
Application received  3/22/2017 DONE
This permit was created on the web by John Humphreys