Permit Information
Permit NumberELE17-01363
StatusFinaled
Name POWERHOUSE ELECTRIC
Site Address 4782 S SPOTTED HORSE AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: new home
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/16/20178/17/20178/17/2017APASS
DetailsJames Ady
garage code 0524 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
Electrical Rough-In5/17/20175/18/20175/18/2017APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover
Permanent Service5/18/20175/18/20175/18/2017PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Darryn Coburn
p/s u/g n ok
Rough-In Permanent Service5/16/20175/17/20175/17/2017AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Darryn Coburn
210.52(I)- Entry way or foyer over 60 sq. ft. shall have a receptacle outlet installed on walls 3' wide or more.
240.24- Operating handle of a over current device shall not be higher than 6'7".
250.134- Metal box in net panel shall be connected to equipment grounding conductor.
300.4- NM coble shall be protected from physical damage where run thru bored hole that does not maintain 1 1/4" from framing surface. 10-3 below panel to left outer wall.
Issue PAID IN FULL permit  5/8/2017 DONE
Payment received via Govolutions
Application received  5/8/2017 DONE
This permit was created on the web by Darryn Coburn