Final | 9/12/2017 | 9/12/2017 | 9/12/2017 | P | PASS |
Tom Saunders
|
|
|
Please call 20 min prior so I can have someone meet you. Phone #: ###-#### Inspection requested via web by Kevin Burke...
ok to final
|
Final | 8/8/2017 | 8/9/2017 | 8/9/2017 | A | NR |
Tom Saunders
|
|
|
Please call 20 min prior. Thanks! Phone #: ###-#### Inspection requested via web by Kevin Burke...
pedestal needs put back together, exposed romex inside needs protected, romex outside needs protected, light needs hung properly in bath...job needs completed
|
Final | 8/2/2017 | 8/3/2017 | 8/3/2017 | A | FAIL |
Tom Saunders
|
|
|
Thomas-please call parcel owner to meet 30 meets prior Phone #: ###-####...
not ready...exposed wires at junction box and panel...never went inside
|
Final | 8/1/2017 | 8/2/2017 | 8/2/2017 | A | CANC |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Kevin Burke...
unable to do inspection until owner/contractor of residence gets permit issues satisfied with city of boise
|
Electrical Rough-In | 6/29/2017 | 6/30/2017 | 6/30/2017 | A | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Kevin Burke...
corrections made...ok to cover
|
Electrical Rough-In | 6/28/2017 | 6/29/2017 | 6/29/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Kevin Burke 300.4- Where NM cable is run thru bored or notched holes that do not maintain 1 1/4" for framing surface nail plates shall protect from physical damage. 334.30- NM cable shall be secured with in 12" of entering panel. 550.15(H)(1)- Under chassis wiring shall be identified for wet locations. NM not wet location rated. Contractor stated all interior circuits have been checked for shorts and damage. OK to energize panel.
|
Change Status to I | | | 6/28/2017 | | DONE |
|
|
|
|
Temporary Service | 6/13/2017 | 6/14/2017 | 6/14/2017 | A | PASS |
Mark Moncarr
|
|
|
t/s u/g rec ok. Mobile home pedistal being used for temp power to work on mobile home. Pedistal already metered, just needs power restored.
|
Conference | 6/13/2017 | 6/13/2017 | 6/13/2017 | P | PASS |
Tom Saunders
|
|
|
view notes on temp service inspection of 6/13/17
|
Temporary Service | 6/13/2017 | 6/13/2017 | 6/13/2017 | P | PASS |
Tom Saunders
|
|
|
Call half hour before // Thomas Phone #: ###-####...
discussed what needed to be done to get temp power at jobsite to do work on mobile home that caught fire...will remove all power feeds to mobile home and use existing pedestal for temp power for time being...will add 4sq box with in-use cover and gfi protection on pedestal
|
Temporary Service | 6/13/2017 | 6/14/2017 | 6/13/2017 | A | CANC |
Tom Saunders
|
|
|
Call half hour before // Thomas Phone #: ###-####
|
Application received | | | 6/13/2017 | | DONE |
|
|
|
This permit was created on the web by Kevin Burke
|
Issue PAID IN FULL permit | | | 6/13/2017 | | DONE |
|
|
|
Paid over the phone
|