Final | 10/10/2017 | 10/11/2017 | 10/11/2017 | A | PASS |
James Ady
|
|
|
Code 2010 Phone #: ###-#### Inspection requested via web by danny perrine Corrections made final ok
|
Final | 10/5/2017 | 10/5/2017 | 10/5/2017 | P | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by danny perrine 210.52 A 2. Wall more than 2ft shall have recep. (Behind master bed door) Hood not installed. Exposed romex hanging in opening.
|
Electrical Rough-In | 6/27/2017 | 6/28/2017 | 6/28/2017 | P | CANC |
James Ady
|
|
|
Soffit cans only Phone #: ###-#### Inspection requested via web by danny perrine Called in wrong permit
|
Rough-In Permanent Service | 6/20/2017 | 6/21/2017 | 6/21/2017 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by danny perrine Corrections made rough in ok p/s u/g n ok
|
Rough-In Permanent Service | 6/19/2017 | 6/20/2017 | 6/20/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by danny perrine 210.52- Up loft receptacles more than 12' apart. Shelving being installed on these walls. 314.17(C)- NM cable sheath shall enter box minimum of 1/4". Smoke by stair. 334.30- MN cable shall be secured with in 12" of a box or stub. Pool wire, AC wire, WP of garage, entry recept., sunroom under window. 422.12- Furnace max amperage 14.8 amp x 125%= 18.5, 20 amp circuit required. 300.4- Nail plates needed where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface. James said OK to foam seal.
|
Issue PAID IN FULL permit | | | 6/14/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/14/2017 | | DONE |
|
|
|
This permit was created on the web by danny perrine
|