Final | 8/1/2017 | 8/2/2017 | 8/2/2017 | A | PASS |
Rock A. Hudson
|
|
|
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|
Final | 8/1/2017 | 8/2/2017 | 8/1/2017 | A | CANC |
Tom Saunders
|
|
|
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn..
scheduled twice
|
Rough-In Permanent Service | 6/23/2017 | 6/23/2017 | 6/23/2017 | P | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn p/s u/g n ok
|
Rough-In Permanent Service | 6/22/2017 | 6/23/2017 | 6/23/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.52- Up bed a receptacle outlet shall be installed with in 6' of door on back side of door. 300.4- NM cable shall be protected from physical damage where run thru hole that does not maintain 1 1/4" from framing surface. Back single garage outside corner, above WP on back of garage. 334.30- NM shall be secured with in 12" of box. Refer.
|
Issue PAID IN FULL permit | | | 6/20/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/20/2017 | | DONE |
|
|
|
This permit was created on the web by Darryn Coburn
|