Final | 10/30/2017 | 10/31/2017 | 10/31/2017 | A | PASS |
Rock A. Hudson
|
|
|
Mark Phone #: ###-#### Final ok
|
Final | 10/26/2017 | 10/27/2017 | 10/27/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Ron Phone #: ###-#### 200.7(C)(1)- White conductor used for other than grounded conductor shall be re-identified. AC ungrounded conductor. 210.8- All GFCI devices shall be installed in a readily accessible location. Garage door GFI. 210.8(A)(5)- Receptacles outlets installed in unfinished areas shall have GFCI protection. Garage loft. 210.11(C)(3)- All receptacle outets installed in bathroom locations shall be on a 20 amp circuit. Powder bath 12ga installed on a 15 amp breaker. 210.63- A receptacle outlet shall be installed with in 25' of outdoor HVAC equipment. 210.70(A)(2)- Required lighting outlet located at garage lower man door not working. (Bulbs) 334.15(B)- Horizontal runs of NM cable in garage loft shall be protected from physical damage due to area unfinished. 422.31- A disconnecting means shall be provided for permenantly installed hood. 110.25 lockout acceptable.
|
Permanent Service | 10/19/2017 | 10/20/2017 | 10/20/2017 | P | PASS |
Mark Moncarr
|
|
|
Ron Phone #: ###-#### p/s u/g n ok
|
Final | 10/18/2017 | 10/19/2017 | 10/19/2017 | P | CANC |
Mark Moncarr
|
|
|
Ron Phone #: ###-####
|
Electrical Rough-In | 9/26/2017 | 9/27/2017 | 9/27/2017 | P | PASS |
Mark Moncarr
|
|
|
Ron Phone #: ###-#### Ok cover detached garage.
|
Electrical Rough-In | 8/30/2017 | 8/30/2017 | 8/30/2017 | P | PASS |
Mark Moncarr
|
|
|
for radiant floor heating only // Ron Phone #: ###-#### Ok cover floor heat mstr
|
Electrical Rough-In | 8/9/2017 | 8/9/2017 | 8/9/2017 | P | PASS |
Mark Moncarr
|
|
|
Underground // Ron Phone #: ###-#### Ok cover
|
Electrical Rough-In | 6/28/2017 | 6/29/2017 | 6/29/2017 | A | PASS |
Mark Moncarr
|
|
|
Ron Phone #: ###-#### ok cover
|
Issue PAID IN FULL permit | | | 6/26/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/26/2017 | | DONE |
|
|
|
This permit was created on the web by ron ormerod
|