Final | 12/2/2019 | 12/2/2019 | 12/2/2019 | P | PASS |
Mark Moncarr
|
|
|
Scott Phone #: ###-#### Ok final. Items addressed were corrected.
|
Final | 11/7/2019 | 11/8/2019 | 11/8/2019 | A | NR |
Mark Moncarr
|
|
|
Scott Phone #: ###-#### 1 recept entry not working. GFI in bed for 2 recpets within 6' of sink. Strap needed for AC, filler piece needed for siding where outside recept is located.
|
ELE-Aging Inspection | 10/8/2019 | 10/8/2019 | 10/9/2019 | | DONE |
Mark Moncarr
|
|
|
Please schedule a final inspection.
|
ELE-Request for Extension | 4/9/2019 | 7/19/2019 | 7/19/2019 | A | PASS |
Daryl DeGrange
|
|
|
This request for extension counts as two Requests, ok until 7/19/2019 A required inspection will need to be requested & passed in order to update the permit 180 days; Phone #: ###-#### job still under construction, Extension request ok
|
ELE-Aging Inspection | 7/9/2019 | 7/9/2019 | 7/9/2019 | | DONE |
Mark Moncarr
|
|
|
Please call with progress on job or schedule a final inspection.
|
Electrical Rough-In | 9/12/2017 | 9/13/2017 | 9/13/2017 | A | PASS |
Mark Moncarr
|
|
|
Scott Phone #: ###-#### p/s o/h rec ok
|
Electrical Rough-In | 8/31/2017 | 9/1/2017 | 9/1/2017 | A | PASS |
Mark Moncarr
|
|
|
Scott Phone #: ###-#### Ok cover
|
Conference | 7/24/2017 | 7/25/2017 | 7/25/2017 | A | DONE |
Rock A. Hudson
|
|
|
Please call ahead for access - Scott Phone #: ###-#### Discussed all codes covering residential wiring. Service change required due to unfused conductors entering structure. Discussed mast, disconnect, grounding electrode system, plumbing and ground rod. Panel location is partially covered by water heater, new location required, mey use as junction point. Talked receptacle spacing for habitable rooms and kitchen counter top areas and bathroom dedicated 20 amp and location. All junction points shall be accessible, saw old and new splices. Discussed tamper resistant type and weather resistant type receptacles. GFCI protection for all bath, outdoor, kitchen counter top receptacles, AFCI protection for new wiring in bedrooms, only new in master bed planned. Scope of work to include new master bed and bath, kitchen area, laundry area and service. Informed homeowners are required to do work with help from immediate family only.
|
Application received | | | 7/24/2017 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 7/24/2017 | | DONE |
|
|
|
|