Permit Information
Permit NumberELE17-02434
StatusExpired
Name AHERN DENNIS
Site Address 4507 W FREEMONT ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Replace 100 amp service with updated 200 amp service.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
ELE-Aging Inspection10/9/201910/9/201910/11/2019 FAIL
DetailsRock A. Hudson
No response from previous attemps.
Doc expired
DOC - Permit Expired10/11/201910/11/201910/11/2019PPASS
DetailsRock A. Hudson
Doc expire OK
ELE-Aging Inspection7/9/20197/9/20197/17/2019 FAIL
DetailsRock A. Hudson
Called owner, no answer, left message about open permit on property and asked to request a final inspection or call to inform of progress of job.
Electrical Rough-In12/5/201712/5/201712/5/2017PPASS
DetailsRock A. Hudson
I should be ready after 12:00 to have you reinspect. If you give me call I''ll make sure I''m there. Thanks for working with me on this! Phone #: ###-#### Inspection requested via web by Dennis Ahern p/s o/h rec ok
Rough-In Permanent Service12/4/201712/5/201712/5/2017AFAIL
DetailsRock A. Hudson
I''m replacing my panel today and would like an inspection late in the day to make sure I get it all in. Please call ahead to confirm I am ready for inspection. Thanks! 208 841 7286. Phone #: ###-#### Conference noted on ELE17-02435. 200.6- Grounded conductors larger than #6 shall be identified with white markings at terminations points.
250.24- Grounding electrode system shall be connected to grounded conductor a main disconnecting means.
250.52- Ground rod gronding electrode system shall be supplemented by additional rod or metal piping system.
250.66- If metal underground water pipe present a minimum of #4 copper grounding electrode conductor shall connect with in 5' of entrance to crawl space.
358.30, 42- Emt Connectors shall be tight and shall be secured with in 3' of top and bottom.
Rough-In Permanent Service12/4/201712/4/201712/4/2017PNR
DetailsRock A. Hudson
I''m replacing my panel today and would like an inspection late in the day to make sure I get it all in. Please call ahead to confirm I am ready for inspection. Thanks! 208 841 7286. Phone #: ###-#### Inspection requested via web by Dennis Ahern
Called contact to check on progress and was asked to reschedule for next day in AM due to not being ready.
Issue PAID IN FULL permit  7/27/2017 DONE
Payment received via Govolutions
Application received  7/27/2017 DONE
This permit was created on the web by Dennis Ahern