ELE-Aging Inspection | 10/9/2019 | 10/9/2019 | 10/11/2019 | | FAIL |
Rock A. Hudson
|
|
|
No response from previous attemps. Doc expired
|
DOC - Permit Expired | 10/11/2019 | 10/11/2019 | 10/11/2019 | P | PASS |
Rock A. Hudson
|
|
|
Doc expire OK
|
ELE-Aging Inspection | 7/9/2019 | 7/9/2019 | 7/17/2019 | | FAIL |
Rock A. Hudson
|
|
|
Called owner, no answer, left message about open permit on property and asked to request a final inspection or call to inform of progress of job.
|
Electrical Rough-In | 12/5/2017 | 12/5/2017 | 12/5/2017 | P | PASS |
Rock A. Hudson
|
|
|
I should be ready after 12:00 to have you reinspect. If you give me call I''ll make sure I''m there. Thanks for working with me on this! Phone #: ###-#### Inspection requested via web by Dennis Ahern p/s o/h rec ok
|
Rough-In Permanent Service | 12/4/2017 | 12/5/2017 | 12/5/2017 | A | FAIL |
Rock A. Hudson
|
|
|
I''m replacing my panel today and would like an inspection late in the day to make sure I get it all in. Please call ahead to confirm I am ready for inspection. Thanks! 208 841 7286. Phone #: ###-#### Conference noted on ELE17-02435. 200.6- Grounded conductors larger than #6 shall be identified with white markings at terminations points. 250.24- Grounding electrode system shall be connected to grounded conductor a main disconnecting means. 250.52- Ground rod gronding electrode system shall be supplemented by additional rod or metal piping system. 250.66- If metal underground water pipe present a minimum of #4 copper grounding electrode conductor shall connect with in 5' of entrance to crawl space. 358.30, 42- Emt Connectors shall be tight and shall be secured with in 3' of top and bottom.
|
Rough-In Permanent Service | 12/4/2017 | 12/4/2017 | 12/4/2017 | P | NR |
Rock A. Hudson
|
|
|
I''m replacing my panel today and would like an inspection late in the day to make sure I get it all in. Please call ahead to confirm I am ready for inspection. Thanks! 208 841 7286. Phone #: ###-#### Inspection requested via web by Dennis Ahern Called contact to check on progress and was asked to reschedule for next day in AM due to not being ready.
|
Issue PAID IN FULL permit | | | 7/27/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/27/2017 | | DONE |
|
|
|
This permit was created on the web by Dennis Ahern
|