Final | 9/11/2017 | 9/12/2017 | 9/12/2017 | A | PASS |
Rock A. Hudson
|
|
|
Call half hour before I can meet you there. Thanks Phone #: ###-#### Inspection requested via web by mark hood Final ok
|
Final | 9/11/2017 | 9/11/2017 | 9/11/2017 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by mark hood 210.8- All devices providing GFCI protection shall be located in a readily accessible location. 300.15- A box shall be installed at all splice points. Flood light located on house garage soffit hanging on wires without a box at time of inspection. BCC 4-05-32- Code violations not to be retained. 406.9(B)(1)- All 15 and 20 amp 120 volt receptacle outlets located in a wet location shall be (WR) weather resistant type.
|
Electrical Rough-In | 8/23/2017 | 8/23/2017 | 8/23/2017 | P | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by mark hood....
rough ok to cover
|
Issue PAID IN FULL permit | | | 8/8/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/8/2017 | | DONE |
|
|
|
This permit was created on the web by mark hood
|