Final | 8/7/2018 | 8/7/2018 | 8/7/2018 | P | PASS |
Rock A. Hudson
|
|
|
Jose Phone #: ###-#### Work completed by contractor ELE17-03593. No temp pole on lot. Final ok
|
Conference | 10/4/2017 | 10/5/2017 | 10/5/2017 | A | DONE |
Daryl DeGrange
|
|
|
Jose Phone #: ###-#### please call to meet-also wants temp servive insp at same time Discuss with homeowner electrical requirements for temporary power source for demolition of dwelling structure.
|
Temporary Service | 10/4/2017 | 10/5/2017 | 10/5/2017 | A | FAIL |
Daryl DeGrange
|
|
|
Jose Phone #: ###-####-please call to meet NEC 406.9(A) Damp locations all 15 and 20 ampere 120 volt receptacle installed outdoors shall have an enclosure for the receptacle that is weatherpoof NEC 590.6 Ground Fault Protection for personal 120 and 240 volt receptacles shall have GFCI protection, ins
|
Application received | | | 10/4/2017 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 10/4/2017 | | DONE |
|
|
|
|