Final | 2/22/2018 | 2/23/2018 | 2/23/2018 | P | PASS |
Rock A. Hudson
|
|
|
Daniel Phone #: ###-#### Final ok
|
Final | 2/7/2018 | 2/8/2018 | 2/8/2018 | A | FAIL |
James Ady
|
|
|
Daniel Phone #: ###-#### 210.8A1 and A7. GFCI protection requiered in bathrooms and within 6ft of sinks. (Bad bathroom GFCI breaker, Laundry room recep and Down bar receps. 314.20. Boxes set back more than 1/4in shall have spark rings,(all receps maounted in tile back splash) 406.12 All dwelling receps shall be Tamper resistant. (GFCI receps in Kitchen)
|
Electrical Rough-In | 10/22/2017 | 10/23/2017 | 10/23/2017 | P | PASS |
James Ady
|
|
|
Wires stapled, other items addressed. Phone #: ###-#### Inspection requested via web by Daniel Dow Master bed, Bath, Living and kitchen. Kitchen recep layout ok as sheet rock was not removed on e wall. Basement mechanical room all ok to cover
|
Electrical Rough-In | 10/19/2017 | 10/20/2017 | 10/20/2017 | P | NR |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Daniel Dow needed conference
|
Conference | 10/20/2017 | 10/20/2017 | 10/20/2017 | P | DONE |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Daniel Dow Talked about wire support, AFCI protection on added receps in Master bed, 1/4in Sheathing in boxes, Grounding conductors tied through, Need recep added on wall in kitchen by Peninsula
|
Issue PAID IN FULL permit | | | 10/13/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/13/2017 | | DONE |
|
|
|
This permit was created on the web by Daniel Dow
|