Permit Information
Permit NumberELE17-03473
StatusFinaled
Name MOUNTAIN POWER ELECT
Site Address 4008 W EDGEMONT ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: House remodel and temp pole
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/17/20181/17/20181/17/2018PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kevin Perez
Final ok
Final1/3/20181/3/20181/3/2018PFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kevin Perez
BCC 4-05-17(C)- It shall be unlawful to impede inspector. House staged prior to inspectoin. Unable to check all receptacles.
110.3- Devices shall be wired as per instructions. Stair 3 way switch miswire. Master bath GFCI will not hold for test.
210.8- Washer receptacle located with in 6' of a sink shl have GFCI protection. Recetpacles located in unfinished basement room shall have GFCI protection.
210.12- Master bed and down bed shall have AFCI protection. Breakers labeled GFCI only.
210.52(B)- Receptacle for island counter top shall be located with in 6" of overhang.
210.52(D)- Required bathroom receptacles shall be located adjacent to each basin. Add additional for 2nd down bath basin.
210.70- Luminaire shall be installed at each door with exterior access. Basement patio light needs installed.
422.30- Water heater shall have a disconnecting means with in sight of appliance. 110.25 lockout acceptable.
Permanent Service12/18/201712/18/201712/18/2017PPASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Kevin Perez
p/s u/g n ok
Electrical Rough-In12/13/201712/13/201712/13/2017PPASS
DetailsRock A. Hudson
Underground Inspection for service Phone #: ###-#### Inspection requested via web by Kevin Perez
110.3- Expansion joints shall be installed as per manufacturers instructions. Installed upside down. Bell end shall be positioned as to not collect moisture or dirt.
225.32- A disconnecting means shall be provided on house at a readily accessible location either outside on inside at nearest point of entrance of conductors.
expansion joists located above grade. Verbal with Tom on corrections for final.
Underground rough in ok cover
Electrical Rough-In11/3/201711/3/201711/3/2017PPASS
DetailsRock A. Hudson
Rough in for detached garage. Phone #: ###-#### Inspection requested via web by Kevin Perez
Rough in ok cover
Electrical Rough-In11/1/201711/1/201711/1/2017PPASS
DetailsRock A. Hudson
Finish rough-in inspection for basement Phone #: ###-#### Inspection requested via web by Kevin Perez
Basement rough in ok cover
Electrical Rough-In10/25/201710/27/201710/27/2017PPART
DetailsRock A. Hudson
Please call Tom with any questions. Phone #: ###-#### Inspection requested via web by Kevin Perez
Must allow time to move home runs to basement for new panel location.
Main floor only rough in ok cover
Temporary Service10/13/201710/13/201710/13/2017PFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kevin Perez
Temp service require a seperate permit. When a temp service is passed permit automatically finals
Issue PAID IN FULL permit  10/13/2017 DONE
Payment received via Govolutions
Application received  10/13/2017 DONE
This permit was created on the web by Kevin Perez