Final | 2/23/2018 | 2/23/2018 | 2/23/2018 | P | PASS |
Rock A. Hudson
|
|
|
Code 2010 Phone #: ###-#### Inspection requested via web by danny perrine Final ok
|
Final | 2/20/2018 | 2/21/2018 | 2/21/2018 | A | FAIL |
Rock A. Hudson
|
|
|
Code 2010 Phone #: ###-#### Inspection requested via web by danny perrine Garage door openers not installed yet lift door. 110.3- Devices shall be wired as per instructions. 2 receptacles reverse polarity left of fireplace. 300.15- All boxes shall have covers or canopies. Hook up oven, hood, m vanity lts. 422.30- A disconnecting means shall be provided for all permanently connected appliances. Oven, hood.
|
Rough-In Permanent Service | 11/3/2017 | 11/6/2017 | 11/6/2017 | P | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by danny perrine rough in ok p/s u/g n ok
|
Electrical Rough-In | 10/31/2017 | 10/31/2017 | 10/31/2017 | P | PASS |
James Ady
|
|
|
Soffit cans Phone #: ###-#### Inspection requested via web by danny perrine Soffit cans only. UL listing and instalation of Fire Hats only. Soffits ok to cover
|
Issue PAID IN FULL permit | | | 10/31/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/31/2017 | | DONE |
|
|
|
This permit was created on the web by danny perrine
|