Final | 2/27/2018 | 2/28/2018 | 2/28/2018 | A | PASS |
Eric Story
|
|
|
lock box is located on hand rail at bottom of ramp please use access code 3704 Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON Final ok
|
Final | 2/23/2018 | 2/26/2018 | 2/26/2018 | A | FAIL |
Eric Story
|
|
|
lockbox is located on hand rail at bottom of ramp please use access code 3704 Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON All receptacles located within 6' of sink shall have GFCI protection Trim receptacles out in LV cabinet Fix front W/P under meter main
|
Electrical Rough-In | 12/21/2017 | 12/22/2017 | 12/22/2017 | A | PASS |
Eric Story
|
|
|
PLEASE USE LOCK BOX CODE 3704 FOR ACCESS, LOCK BOX IS LOCATED AT BOTTOM OF RAMP Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON Basement corrections fixed, Rough-in ok to cover
|
Conference | 12/11/2017 | 12/13/2017 | 12/13/2017 | A | DONE |
Eric Story
|
|
|
electrical contractor would like to meet with electrical inspector for verification on corrections needing done. 9;30 am is the best time please let me know 1/2 hour before arriving. Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON Discussed corrections given on previous inspections, wall will be reframed for clearences and all corections have been addressed and will have a reinspection on another date once completed.
|
Electrical Rough-In | 12/8/2017 | 12/11/2017 | 12/11/2017 | A | FAIL |
Daryl DeGrange
|
|
|
PLEASE USE LOCK BOX CODE 3704 FOR ACCESS, LOCK BOX IS LOCATED ON BOTTOM OF RAMP - CONTACT ALLEN ELECTRICIAN FOR ANY QUESTIONS ###-#### Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON Not all corrections completed.
|
Electrical Rough-In | 12/8/2017 | 12/8/2017 | 12/8/2017 | P | FAIL |
Rock A. Hudson
|
|
|
Structural inspector called concerning notes from electrical inspection. Last sentence refers to general contractor stating he had conversation with 375 Eric Story about allowing violations with access and work clearences. Eric Story denies having this conversation and would not give anyone permission to do an install not compliant with current NEC.
|
Electrical Rough-In | 11/14/2017 | 11/16/2017 | 11/16/2017 | A | FAIL |
Rock A. Hudson
|
|
|
WIRING WAS FOR BASEMENT REMODEL ONLY, ALL OTHER WIRING INCLUDING SERVICE AND PANEL IN BASEMENT WHERE EXISTING. FOR ACCESS FIND LOCKBOX ON RAILING AT BOTTOM OF LAMP, USE ACCESS CODE 3704. PLEASE CONTACT ALLEN THE ELECTRICIAN FOR ANY QUESTIONS ###-#### Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON 110.26- Minimum work space shall be provided for panel board. 30" wide 36" deep. Panel in basement located behind framed wall ith studs 16" on center. 300.4- Where cables are run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected ftom physical damage by nail plates. Marked by X. 314.29- Boxes located behind framed wall. Box in net panel and box located below net panel shall be accessible. 330.12- MC shall not be installed wher subject to physical damage. Corners cut MC may be damaged when drywall installed. 330.30- MC shall be secured with in 12" of a box. Contact stated general contractor had conversation with electrical inspector about workspace issue and inspector OK with not providing work space. Will address issue with 375 when he returns.
|
Electrical Rough-In | 11/13/2017 | 11/15/2017 | 11/14/2017 | A | CANC |
Eric Story
|
|
|
THERE IS A LOCK BOX LOCATED ON THE RAILING AT THE BOTTOM OF THE RAMP, THE ACCESS CODE 3704. THIS PERMIT IS FOR THE DOWNSTAIRS OFFICE ADDITION ONLY! THE SERVICE AND THE PANEL DOWNSTAIRS ARE ALREADY EXISTING. Phone #: ###-#### >> Inspection requested via web by SHAWN TOMLINSON Inspection cancelled from web by: SHAWN TOMLINSON
|
Issue PAID IN FULL permit | | | 11/10/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/10/2017 | | DONE |
|
|
|
This permit was created on the web by SHAWN TOMLINSON
|
First Notice | 2/28/2018 | 2/28/2018 | | | |
Eric Story
|
|
|
|