Final | 3/1/2018 | 3/2/2018 | 3/2/2018 | P | PASS |
Rock A. Hudson
|
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison Final ok
|
Final | 2/28/2018 | 3/1/2018 | 3/1/2018 | P | FAIL |
Rock A. Hudson
|
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison 110.3- 1 Garage receptacle and outdoor receptacle not working. 210.8- GFCI devices shall be located in a readily accessible location. Patio 210.52(D)- Up green bath shall have a receptacle outlet located adjacent to each basin. 314.23- Box to right of fireplace shall be securely mounted. 314.25- box to right of fireplace shall have a cover installed. 406.12- Outdoor GFCI devices shall be tamper resistant type.
|
Final | 2/26/2018 | 2/28/2018 | 2/28/2018 | A | CANC |
Eric Story
|
|
|
garage code 1234 Phone #: ###-#### >> Inspection requested via web by Jay Hutchison Inspection cancelled from web by: Jay Hutchison
|
Electrical Rough-In | 1/28/2018 | 1/29/2018 | 1/29/2018 | A | PASS |
James Ady
|
|
|
I''m installing the floor heat first thing Monday morning and I was not sure if this required an inspection but the customer is in a hurry to get the tile down and I was trying not to hold them up if it requires an inspection. If not I guess disregard this request. Phone #: ###-#### Inspection requested via web by Jay Hutchison Master floor heat only ok to cover
|
Rough-In Permanent Service | 12/1/2017 | 12/4/2017 | 12/4/2017 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Jay Hutchison rough in ok p/s u/g n ok
|
Issue PAID IN FULL permit | | | 11/27/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/27/2017 | | DONE |
|
|
|
This permit was created on the web by Jay Hutchison
|