Final | 4/13/2018 | 4/13/2018 | 4/13/2018 | P | PASS |
Rock A. Hudson
|
|
|
Call John for entry 30 min prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by John Edwards Final ok
|
Electrical Rough-In | 4/4/2018 | 4/4/2018 | 4/4/2018 | P | PASS |
Rock A. Hudson
|
|
|
Please call 30 minutes prior Phone #: ###-#### Inspection requested via web by John Edwards Bedroom and bathroom addition ok to occupy. Other items corrected.
|
Electrical Rough-In | 2/26/2018 | 2/26/2018 | 2/26/2018 | P | PART |
Rock A. Hudson
|
|
|
please call 30 min. prior Phone #: ###-#### Inspection requested via web by John Edwards Owner moving in inspection to check existing portion of residence. 210.8- Receptacle outets located with in 6' of a sink shall have GFCI protection. Near kitchen sink. 406.4(D)- Grounding type receptacles installed on ungrounded circuits shall be GFCI protected. Unable to locate GFCI devices for existing grounding type receptacles.
|
Electrical Rough-In | 2/23/2018 | 2/26/2018 | 2/26/2018 | A | NH |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by John Edwards House occupied contractor to call in when accessible
|
Electrical Rough-In | 2/14/2018 | 2/14/2018 | 2/14/2018 | P | PASS |
Rock A. Hudson
|
|
|
Homerun stud bay rough in ok cover
|
Rough-In Permanent Service | 2/8/2018 | 2/8/2018 | 2/8/2018 | P | CANC |
Rock A. Hudson
|
|
|
Service change. Phone #: ###-#### Inspection requested via web by John Edwards Service change only, will request inspection for stud bay homeruns are in for supports.
|
Permanent Service | 2/8/2018 | 2/8/2018 | 2/8/2018 | P | PASS |
Rock A. Hudson
|
|
|
Service change. Phone #: ###-#### Inspection requested via web by John Edwards Meter base to remain and main breaker panel below meter changed for breaker space. p/s o/h rec ok
|
Electrical Rough-In | 2/1/2018 | 2/1/2018 | 2/1/2018 | A | PASS |
Rock A. Hudson
|
|
|
please call 30 minutes prior to arrival. Phone #: ###-#### Inspection requested via web by John Edwards Asked to check existing meter base and mast if ok to remain if panel changed out below meter base. As service size not being increased meter base and mast OK to remain, just changing panel due to limited breaker space of existing panel. Bed, bath, and closet addition rough in ok cover.
|
Electrical Rough-In | 1/30/2018 | 1/30/2018 | 1/30/2018 | P | PASS |
Eric Story
|
|
|
Cover inspection for basement and maybe upstairs bedroom Phone #: ###-#### Inspection requested via web by John Edwards Downstairs and hall bath ok to cover
|
Electrical Rough-In | 1/17/2018 | 1/17/2018 | 1/17/2018 | P | PASS |
Rock A. Hudson
|
|
|
John Phone #: ###-#### Addition being framed, basement not ready, main level kitchen area rough in ok cover.
|
Conference | 1/3/2018 | 1/3/2018 | 1/3/2018 | P | DONE |
Rock A. Hudson
|
|
|
Kitchen remodel/new addition. Call Jimmy prior to arrival to meet you there. ###-#### Phone #: ###-#### Inspection requested via web by John Edwards Discussed areas of existing dwelling that will require updating. BCC 4-05-32- Code violations not to be retained. Split bus panel ok to remain as long as number of disconnecting means does not exceed 6. All conduits and cables installed in wet locations shall be rated for such location. House has a large number of junction boxes which shall remain accessible. Laundry circuit shall be added to laundry room in basement. Bathroom plumbing being replaced, wiring ok to remain. New work to include relocating kitchen area and adding bed and bath to east side of dwelling.
|
Issue PAID IN FULL permit | | | 12/29/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/29/2017 | | DONE |
|
|
|
This permit was created on the web by John Edwards
|