Permit NumberELE18-00987
StatusFinaled
Name ROBERTSON ELECTRIC
Site Address 2323 N HEIGHTS DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: Complete wiring of a single family home
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/27/20186/28/20186/28/2018PPASS
DetailsMark Moncarr
Garage code is 7352 Phone #: ###-#### Inspection requested via web by Zane Robertson Ok final.
Electrical Rough-In5/23/20185/24/20185/24/2018APASS
DetailsMark Moncarr
Floor heat in master bathroom and hall bath the garage code is 6288 enter Phone #: ###-#### Inspection requested via web by Zane Robertson Ok cover floor heat mstr and main bath. Talked to contractor about pulling cold leads out of wall and installing in floor. I received pics of correct install.
Rough-In Permanent Service3/20/20183/20/20183/20/2018PPASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Zane Robertson p/s u/g n ok. Corrections made.
Rough-In Permanent Service3/19/20183/20/20183/20/2018AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Zane Robertson
110.3- Power to chime transformer missed. 250.24(A)(5)- Grounded conductor shall not be connected to ground on the loadside of service disconnecting means. Remove grounding electrode conductor from sub panel.
314.17(A)- Open KO in entry 3/0 box. Shall close KO with approved means.
314.25- All boxes shall have covers. Recessed can in powder bath missing junction box cover.
Issue PAID IN FULL permit  3/15/2018 DONE
Payment received via Govolutions
Application received  3/15/2018 DONE
This permit was created on the web by Zane Robertson