Final | 8/20/2018 | 8/20/2018 | 8/20/2018 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Troy Cobb Final ok
|
Conference | 8/20/2018 | 8/20/2018 | 8/20/2018 | A | PASS |
James Ady
|
|
|
Just need to clarify some things from the inspection on Friday. We might be able to handle it with a phone call Phone #: ###-#### Inspection requested via web by Troy Cobb After discussing with Troy, Down bed receps will not need added. Walls were not opened up. All others corrections need addressed.
|
Final | 8/16/2018 | 8/17/2018 | 8/17/2018 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Troy Cobb BCC 04-05-32- No code violation shall be retained. Hot tub TA, Bonding rain gutter, Missing covers and outdoor covers. 110.3- Reverse polarity washer receptacle. 110.27- All NM located below 8' shall be protected from damage. Master bath, above panel. 210.8- Washer receptacle located with in 6' of a sink shall have GFCI protection. 210.52- Receptacles shall serve wall space 24" and wider and no point measured along floor line shall be more than 6' from a receptacle outlet. Down stairs bed each side of door, master bed each side of fireplace 6' of wall space each side. Room straight back from entry over 12' between receptacle and 1 recept. not workng. 314.20- Spark rings needed for receptacles located in stone where boxes 1/4" or more in non combustible materials. 406.6- All receptacles shall have covers, outdoor back of house and master bed. 410.16- Recessed cons located in master closet area shall have totally enclosed lamps. 680.26(B)(7)- Fixed metal located with in 5" horizontal and 12" vertical of hot tub water edge shall be bonded to hot tub equipment.
|
Electrical Rough-In | 4/16/2018 | 4/16/2018 | 4/16/2018 | P | PASS |
James Ady
|
|
|
Top floor was already inspected before we took over the job. In case nobody is there the garage door can be raised up by hand. Phone #: ###-#### Inspection requested via web by Troy Cobb entry, soffits and basement ok to cover
|
Application received | | | 4/3/2018 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 4/3/2018 | | DONE |
|
|
|
|